Purpose: Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy V R , proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice. Material and methods: A multicenter (n ¼ 15) dosimetric analysis of five different techniques for CSI (3D-CRT, IMRT, VMAT, TomoTherapy V R , PBS; 3 centers per technique) was performed using the same patient data, set of delineations and dose prescription (36.0/1.8 Gy). Different treatment plans were optimized based on the same planning target volume margin. All participating institutes returned their best treatment plan applicable in clinic. Results: The modern radiotherapy techniques investigated resulted in superior conformity/homogeneity-indices (CI/HI), particularly in the spinal part of the target (CI: 3D-CRT:0.3 vs. modern:0.6; HI: 3D-CRT:0.2 vs. modern:0.1), and demonstrated a decreased dose to the thyroid, heart, esophagus and pancreas. Dose reductions of >10.0 Gy were observed with PBS compared to modern photon techniques for parotid glands, thyroid and pancreas. Following this technique, a wide range in dosimetry among centers using the same technique was observed (e.g., thyroid mean dose: VMAT: 5.6-24.6 Gy; PBS: 0.3-10.1 Gy). Conclusions: The investigated modern radiotherapy techniques demonstrate superior dosimetric results compared to 3D-CRT. The lowest mean dose for organs at risk is obtained with proton therapy. However, for a large number of organs ranges in mean doses were wide and overlapping between techniques making it difficult to recommend one radiotherapy technique over another.
ARTICLE HISTORY
Clinically relevant intensity modulated proton therapy (IMPT) treatment plans were measured in a newly developed anthropomorphic phantom (i) to assess plan accuracy in the presence of high heterogeneity and (ii) to measure plan robustness in the case of treatment uncertainties (range and spatial). The new phantom consists of five different tissue substitute materials simulating different tissue types and was cut into sagittal planes so as to facilitate the verification of co-planar proton fields. GafChromic films were positioned in the different planes of the phantom, and 3D-IMPT and distal edge tracking (DET) plans were delivered to a volume simulating a skull base chordoma. In addition, treatments planned on CTs of the phantom with HU units modified were delivered to simulate systematic range uncertainties (range-error treatments). Finally, plans were delivered with the phantom rotated to simulate spatial errors. Results show excellent agreement between the calculated and the measured dose distribution: >99% and 98% of points with a gamma value <1 (3%/3 mm) for the 3D-IMPT and the DET plan, respectively. For both range and spatial errors, the 3D-IMPT plan was more robust than the DET plan. Both plans were more robust to range than to the spatial uncertainties. Finally, for range error treatments, measured distributions were compared to a model for predicting delivery errors in the treatment planning system. Good agreement has been found between the model and the measurements for both types of IMPT plan.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.