Background: Dressing of split-thickness skin graft donor sites can be traumatic for the patient. The most advanced and expensive dressings have been compared to the most basic of dressings, with little or no consensus and an unpersuasive level of evidence. We aimed to determine the efficacy of the locally manufactured non-adherent, hydroconductive Drawtex® dressing and compare it to our current standard-of-care dressing, a thin transparent polyurethane film, in the healing of split-thickness donor sites. Methods: This prospective, within-patient controlled study included 27 adult participants, each with two split-thickness skin donor sites. The 54 donor site wounds were compared with regard to time to re-epithelialisation, perceived pain and healed wound quality. Results: By day 5, complete healing of donor site wounds, defined as >90% of epithelialized surface, was significantly higher in the hydroconductive dressing group compared to the polyurethane film group (22.2% and 3.7%, respectively; p < 0.0001). The hydroconductive dressing-treated donor site wounds were significantly less painful at 24-hours, *A research report on the original work presented in this article has been approved in partial fulfilment of the requirements for the degree of Master of Medicine by the University of the Witwatersrand.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.