Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) was introduced to decrease wear debris and osteolysis. During cross-linking, free radicals are formed, making highly cross-linked polyethylene vulnerable to oxidative degradation. In order to reduce this process, anti-oxidant vitamin E can be incorporated in polyethylene. This review provides an overview of the effects of vitamin E incorporation on major complications in total joint arthroplasty: material failure due to oxidative degradation, wear debris and subsequent periprosthetic osteolysis, and prosthetic joint infections. Secondly, this review summarizes the first clinical results of total hip and knee arthroplasties with vitamin E incorporated highly cross-linked polyethylene. Based on in vitro studies, incorporation of vitamin E in polyethylene provides good oxidative protection and preserves low wear rates. Incorporation of vitamin E may have the beneficial effect of reduced inflammatory response to its wear particles. Some microorganisms showed reduced adherence to vitamin E-incorporated UHMWPE; however, clinical relevance is doubtful. Short-term clinical studies of total hip and knee arthroplasties with vitamin E-incorporated highly cross-linked UHMWPE reported good clinical results and wear rates similar to highly cross-linked UHMWPE without vitamin E.
Purpose This systematic review and meta-analysis aimed to study surgical site infection of wound closure using staples versus sutures in elective knee and hip arthroplasties. Methods A systematic literature review was performed to search for randomized controlled trials that compared surgical site infection after wound closure using staples versus sutures in elective knee and hip arthroplasties. The primary outcome was surgical site infection. The risk of bias was assessed with the Cochrane risk of bias assessment tool. The relative risk and 95% confidence interval with a random-effects model were assessed. Results Eight studies were included in this study, including 2 studies with a low risk of bias, 4 studies having ‘some concerns’, and 2 studies with high risk of bias. Significant difference was not found in the risk of SSI for patients with staples (n = 557) versus sutures (n = 573) (RR: 1.70, 95% CI: 0.94–3.08, I2 = 16%). The results were similar after excluding the studies with a high risk of bias (RR: 1.67, 95% CI: 0.91–3.07, I2 = 32%). Analysis of studies with low risk of bias revealed a significantly higher risk of surgical site infection in patients with staples (n = 331) compared to sutures (n = 331) (RR: 2.56, 95% CI: 1.20–5.44, I2 = 0%). There was no difference between continuous and interrupted sutures (P > 0.05). In hip arthroplasty, stapling carried a significantly higher risk of surgical site infection than suturing (RR: 2.51, 95% CI: 1.15–5.50, I2 = 0%), but there was no significant difference in knee arthroplasty (RR: 0.87, 95% CI: 0.33–2.25, I2 = 22%; P > 0.05). Conclusions Stapling might carry a higher risk of surgical site infection than suturing in elective knee and hip arthroplasties, especially in hip arthroplasty.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.