Introduction Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. Methods A total of 441 leads (median: 159 months [135–197]; range: 120–487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. Results The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003–1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow‐up of 31 ± 27 months, 21 patients (11%) died. No procedure‐related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99–21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04–62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48–9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17–8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow‐up. Conclusion Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.
Background: Limited data is available about the outcome of TLE in patients with vs. without high energy leads in the last decade. Methods: This is an analysis of consecutive patients undergoing TLE at a high-volume TLE centre from 2001 to 2021 using the stepwise approach. Baseline characteristics, procedural details and outcome of patients with high energy lead (ICD group) vs. without high energy lead (non-ICD group) were compared. Results: Out of 667 extractions, 991 leads were extracted in 405 procedures (60.7%) in the ICD group and 439 leads in 262 procedures (39.3%) in the non-ICD group. ICD patients were significantly younger (median 67 vs. 74 years) and were significantly less often female (18.1% vs. 27.7%, p < 0.005 for both). Advanced extraction tools were used significantly more often in the ICD group (73.2% vs. 37.5%, p < 0.001), but there were no significant differences in the successful removal (98.8% vs. 99.2%) or complications (4.7% vs. 3.1%) between the groups (p > 0.2 for both). Discussion: Using the stepwise approach, overall procedural success was high and complication rate was low in a high-volume centre. In patients with a high energy lead, the TLE procedure was more complex, but outcome was similar to comparator patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.