Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm2 after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms.
f Infections caused by carbapenem-resistant KPC-producing Klebsiella pneumoniae are responsible for high rates of mortality and represent a major therapeutic challenge, especially when the isolates are also resistant to colistin. We used the checkerboard method to evaluate the synergistic activity of 10 antibiotic combinations against 13 colistin-resistant KPC-producing K. pneumoniae isolates (colistin MIC range of 8 to 128 mg/liter). Colistin plus rifampin was the only combination that demonstrated consistent synergistic bacteriostatic activity against 13/13 strains tested, reducing the colistin MIC below the susceptibility breakpoint (MIC < 2 mg/liter) in 7/13 strains at rifampin concentrations ranging from 4 to 16 mg/liter. Bactericidal synergistic activity was also documented for 8/13 tested strains. Other antimicrobial combinations with carbapenems, gentamicin, and tigecycline showed variously synergistic results. Colistin plus rifampin also exhibited bacteriostatic synergistic activity against 4/4 colistin-susceptible KPC-producing K. pneumoniae isolates (colistin MIC range of 0.5 to 2 mg/liter) and 4/4 ertapenem-resistant extended-spectrum beta-lactamase (ESBL)-producing K. pneumoniae isolates (ertapenem MIC range of 16 to 32 mg/liter). Collectively, our data suggest that colistin plus rifampin is the most consistently synergistic combination against KPC-producing K. pneumoniae isolates, including colistin-resistant strains. Colistin-rifampin combinations may have a role in the treatment of multidrug-resistant K. pneumoniae and may possibly slow the selection of heteroresistant subpopulations during colistin therapy.
A carbapenem-sparing regimen of tigecycline plus gentamicin or colistin was effective for treating 24 of 26 (92%) Klebsiella pneumoniae carbapenemase-producing K. pneumoniae infectious episodes in 22 polytrauma intensive care unit patients without comorbidities. The 30-day crude mortality rate was 14%. Regimens were considered appropriate in 12% of episodes according to the Vitek 2 System and in 100% based on E-test.
The presence of pathogenic viruses in healthcare settings represents a serious risk for both staff and patients. Direct viral detection in the environment poses significant technical problems and the indirect indicators currently in use suffer from serious limitations. The aim of this study was to monitor surfaces and air in hospital settings to reveal the presence of hepatitis C virus, human adenovirus, norovirus, human rotavirus and torque teno virus by nucleic acid assays, in parallel with measurements of total bacterial count and haemoglobin presence. In total, 114 surface and 62 air samples were collected. Bacterial contamination was very low (<1 cfu/cm(2)) on surfaces, whereas the 'medium' detected value in air was 282 cfu/m(3). Overall, 19 (16.7%) surface samples tested positive for viral nucleic acids: one for norovirus, one for human adenovirus and 17 (14.9%) for torque teno virus (TTV). Only this latter virus was directly detected in 10 air samples (16.1%). Haemoglobin was found on two surfaces. No relationship was found between viral, biochemical or bacterial indicators. The data obtained confirm the difficulty of assessing viral contamination using bacterial indicators. The frequent detection of TTV suggests its possible use as an indicator for general viral contamination of the environment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.