A highly sensitive spectrofluorimetric method has been developed for the determination of 2-ethylhexyl nitrate in diesel fuel. Usually, this compound is used as an additive in order to improve cetane number.The analytical method consists in building the chemometric model as a first step. Then, it is possible to quantify the analyte with only recording a single excitation-emission fluorescence spectrum (EEF), whose data are introduced in the chemometric model above mentioned. Another important characteristic of this method is that the fuel sample was used without any pre-treatment for EEF.This work provides an interest improvement to fluorescence techniques using the rapid and easily applicable EEF approach to analyze such complex matrices. Exploding EEF was the key to a successful determination, obtaining a detection limit of 0.00434% (v/v) and a limit of quantification of 0.01446% (v/v overlapping of the spectral information might be overcome by using multicomponent analysis such as partial least squares (PLS) [21]. This method allowed an approach using the full spectral region rather than unique and isolated analytical bands. PLS performs data decomposition into spectral score and loading matrices prior to model building with the aid of these new variables, using spectral and concentration data. The algorithm was based on the ability to mathematically correlate spectral data to a property of interest while simultaneously accounting for all other significant spectral factors that interfered in the spectrum.The full cross-validation leave-one-out procedure was applied, which consists of systematically removing one of the training samples in turn, and using only the remaining ones for the construction of the latent factors and regression models [22].The predictive capability of calibration model was expressed by the determination coefficient (R-square), root mean square error of cross validation (RMSECV), and standard error of prediction (SEP).The optimal number of principal components (PCs) was chosen in function of the first local minimum based on the RMSEC curve after cross validation in the calibration set. Predictive capability of model was evaluated by predicting the external prediction set with commercial formulation. Results and DiscussionConventional fluorescence may be preferred to determine one fluorophor concentration or when the mixture being analyzed contains only a limited number of compounds with fluorescence properties and a quenching effect are not to be expected. Ignoring the excitation spectra by using only the emission spectra could not be enough to obtain the solutions of the problem. So, besides the emission spectra, it seems essential to include also the analysis of excitation spectra possessing abundant information. The determination in diesel oil may contain many fluourophors. This task is further complicated by the fact that the fluorophors of interest have different characteristic excitation and emission ranges in the different samples. An inherent problem of many fluorimetric ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.