Prevention measures should aim to control and/or reduce the magnitude of frontal bending, lateral bending, and torsion in the trunk, as well as the peak loads, while skiing.
Inertial sensor drift is usually corrected on a single-sensor unit level. When multiple sensor units are used, mutual information from different units can be exploited for drift correction. This study introduces a method for a drift-reduced estimation of three dimensional (3-D) segment orientations and joint angles for motion capture of highly dynamic movements as present in many sports. 3-D acceleration measured on two adjacent segments is mapped to the connecting joint. Drift is estimated and reduced based on the mapped accelerations' vector orientation differences in the global frame. Algorithm validity is assessed on the example of alpine ski racing. Shank, thigh, and trunk inclination as well as knee and hip flexion were compared to a multicamera-based reference system. For specific leg angles and trunk segment inclination mean accuracy and precision were below 3.9° and 6.0°, respectively. The errors were similar to errors reported in other studies for lower dynamic movements. Drift increased axis misalignment and mainly affected joint and segment angles of highly flexed joints such as the knee or hip during a ski turn.
A key point in human movement analysis is measuring the trajectory of a person's center of mass (CoM). For outdoor applications, differential Global Navigation Satellite Systems (GNSS) can be used for tracking persons since they allow measuring the trajectory and speed of the GNSS antenna with centimeter accuracy. However, the antenna cannot be placed exactly at the person's CoM, but rather on the head or upper back. Thus, a model is needed to relate the measured antenna trajectory to the CoM trajectory. In this paper we propose to estimate the person's posture based on measurements obtained from inertial sensors. From this estimated posture the CoM is computed relative to the antenna position and finally fused with the GNSS trajectory information to obtain the absolute CoM trajectory. In a biomechanical field experiment, the method has been applied to alpine ski racing and validated against a camera-based stereo photogrammetric system. CoM position accuracy and precision was found to be 0.08 m and 0.04 m, respectively. CoM speed accuracy and precision was 0.04 m/s and 0.14 m/s, respectively. The observed accuracy and precision might be sufficient for measuring performance-or equipment-related trajectory differences in alpine ski racing. Moreover, the CoM estimation was not based on a movement-specific model and could be used for other skiing disciplines or sports as well.
To obtain valid 3D joint angles with inertial sensors careful sensor-to-segment calibration (i.e. functional or anatomical calibration) is required and measured angular velocity at each sensor needs to be integrated to obtain segment and joint orientation (i.e. joint angles). Existing functional and anatomical calibration procedures were optimized for gait analysis and calibration movements were impractical to perform in outdoor settings. Thus, the aims of this study were 1) to propose and validate a set of calibration movements that were optimized for alpine skiing and could be performed outdoors and 2) to validate the 3D joint angles of the knee, hip, and trunk during alpine skiing. The proposed functional calibration movements consisted of squats, trunk rotations, hip ad/abductions, and upright standing. The joint drift correction previously proposed for alpine ski racing was improved by adding a second step to reduce separately azimuth drift. The system was validated indoors on a skiing carpet at the maximum belt speed of 21 km/h and for measurement durations of 120 seconds. Calibration repeatability was on average <2.7° (i.e. 3D joint angles changed on average <2.7° for two repeated sets of calibration movements) and all movements could be executed wearing ski-boots. Joint angle precision was <4.9° for all angles and accuracy ranged from -10.7° to 4.2° where the presence of an athlete-specific bias was observed especially for the flexion angle. The improved joint drift correction reduced azimuth drift from over 25° to less than 5°. In conclusion, the system was valid for measuring 3D joint angles during alpine skiing and could be used outdoors. Errors were similar to the values reported in other studies for gait. The system may be well suited for within-athlete analysis but care should be taken for between-athlete analysis because of a possible athlete-specific joint angle bias.
This study explored the use of body worn sensors to evaluate the vibrations that act on the human body in alpine ski racing from a general and a back overuse injury prevention perspective. In the course of a biomechanical field experiment, six male European Cup-level athletes each performed two runs on a typical giant slalom (GS) and slalom (SL) course, resulting in a total of 192 analyzed turns. Three-dimensional accelerations were measured by six inertial measurement units placed on the right and left shanks, right and left thighs, sacrum, and sternum. Based on these data, power spectral density (PSD; i.e., the signal's power distribution over frequency) was determined for all segments analyzed. Additionally, as a measure expressing the severity of vibration exposure, root-mean-square (RMS) acceleration acting on the lower back was calculated based on the inertial acceleration along the sacrum's longitudinal axis. In both GS and SL skiing, the PSD values of the vibrations acting at the shank were found to be largest for frequencies below 30 Hz. While being transmitted through the body, these vibrations were successively attenuated by the knee and hip joint. At the lower back (i.e., sacrum sensor), PSD values were especially pronounced for frequencies between 4 and 10 Hz, whereas a corresponding comparison between GS and SL revealed higher PSD values and larger RMS values for GS. Because vibrations in this particular range (i.e., 4 to 10 Hz) include the spine's resonant frequency and are known to increase the risk of structural deteriorations/abnormalities of the spine, they may be considered potential components of mechanisms leading to overuse injuries of the back in alpine ski racing. Accordingly, any measure to control and/or reduce such skiing-related vibrations to a minimum should be recognized and applied. In this connection, wearable sensor technologies might help to better monitor and manage the overall back overuse-relevant vibration exposure of athletes in regular training and or competition settings in the near future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.