We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 microg x kg(-1) x min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-sd) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.0l L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a +/-13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.
Previous studies have suggested that Lingzhi (Ganoderma lucidum) has antioxidant effects and possibly beneficial effects on blood pressure, plasma lipids and glucose, but these have not been confirmed in subjects with mild hypertension or hyperlipidaemia. The objective of the present study was to assess the cardiovascular, metabolic, antioxidant and immunomodulatory responses to therapy with Lingzhi in patients with borderline elevations of blood pressure and/or cholesterol in a controlled cross-over trial. A total of twenty-six patients received 1·44 g Lingzhi daily or matching placebo for 12 weeks in a randomised, double-blind, cross-over study with placebo-controlled run-in and cross-over periods. Body weight, blood pressure, metabolic parameters, urine catecholamines and cortisol, antioxidant status and lymphocyte subsets were measured after each period. Lingzhi was well tolerated and data from twenty-three evaluable subjects showed no changes in BMI or blood pressure when treated with Lingzhi or placebo. Plasma insulin and homeostasis model assessmentinsulin resistance were lower after treatment with Lingzhi than after placebo. TAG decreased and HDL-cholesterol increased with Lingzhi but not with placebo in the first treatment period, but significant carry-over effects prevented complete analysis of these parameters. Urine catecholamines and cortisol, plasma antioxidant status and blood lymphocyte subsets showed no significant differences across treatments. Results indicate that Lingzhi might have mild antidiabetic effects and potentially improve the dyslipidaemia of diabetes, as shown previously in some animal studies. Further studies are desirable in patients with hyperglycaemia.
ACI and the Heather index were the most reliable impedance derived indices of cardiac contractility.
In the vasodilated and septic patient, the impedance method of measuring cardiac output (CO) may underestimate the true value. In this study, we sought to determine whether impedance CO (COIC) measurements are influenced by total peripheral resistance (TPR). In eight anesthetized and ventilated dogs, a high-precision flowprobe was placed on the ascending aorta, and direct CO was measured (CO flowprobe (COFP)). Mean arterial blood pressure was measured from the femoral artery. Simultaneous COIC measurements were made. TPR (mean arterial blood pressure x 80/COFP) was varied over 1-2 h by using infusions of phenylephrine and adrenaline and inhaled halothane. The bias between methods of CO measurement (COIC-COFP) was calculated and compared with TPR by using correlation and regression analysis. A total of 547 pairs of CO measurements were collected from the 8 dogs as TPR was varied. COFP changed by a mean of 190% (range, 89%-425%), and TPR changed by a mean of 266% (range, 94%-580%) during the experiment. The impedance method underestimated CO when TPR was low and overestimated CO when TPR was high. There was a logarithmic relationship between the CO bias and TPR. Correlation coefficients (r) between the CO bias and TPR ranged from 0.46 to 0.89 (P < 0.0001). The bias changed by 0.62 +/- 1.8 L/min, or by 34%, every time TPR halved or doubled. This finding explains the poor agreement between COIC and other methods of CO measurement found in validation studies involving critically ill patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.