Background: Device closure of atrial septal defect (ASD) is a treatment of choice in selected patients with a suitable defect. We aimed to evaluate short- and intermediate-term outcomes with device closure in special reference to complications in Western Indian population. Materials and Methods: The present prospective observational study enrolled 184 patients with ASD who underwent Device closure. All patients were followed at 15–30 days (short) and 3–12 months (intermediate). Results: Device closure of ASD was done successfully in 180 (97.83%) patients. Systolic (P = 0.02), diastolic (P = 0.007), and mean PA (P = 0.0001) pressure were significantly decreased at postprocedure. Residual defect was resolved in 94.2% of patients by 6 months. Preprocedural Pulmonary artery hypertension was found in 36 (19.56%) patients and was reduced in 15 (8.15%) patients postprocedure and in 10 (5.43%) patients at 1 year. Residual shunt was reported in 34% of patients which was resolved in all by 6 months. At postprocedure and follow–up, patients were developed minor complications included (0.5%) moderate MR, 1 (0.5%) lower respiratory tract infection, and 3 (1.6%) local site hematoma. Eleven (5.98%) major complications involved arrythmia (2.17%), infective endocarditis (0.54%), LAA perforation (0.54%), cardioembolic shock (0.54%), device embolization (0.54%), sudden cardiac arrest (0.54%), intraprocedural acute coronary syndrome (0.54%), and cardiac tamponade (0.54%). Conclusion: Device closure appears to be best available option at the present time. Careful attention to the details of the technique is mandatory to achieve a successful outcome in order to avoid complication related to procedure. Patients of all ages experience reduction in pulmonary artery pressure after percutaneous device closure of ASD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.