The performance of point‐of‐use (POU) devices to remove dissolved and particulate lead (Pb) and their effect on tap water quality were investigated in a large building under typical usage patterns and during one year. Both forms of Pb were efficiently removed, although materials downstream of the POU devices slightly increased total Pb levels at the tap. No evidence of POU breakthrough was observed following stagnations carried out before sampling. Although measurements of heterotrophic place counts and total and live bacteria on the POU material itself indicated no significant colonization, small but significant increases in viable bacteria at the tap suggest that colonization occurred in the piping and tap downstream of the POU devices in the absence of chlorine residual. This study suggests that these devices are a useful remediation approach to control Pb in large buildings, providing that building maintenance procedures are issued for POU devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.