Purpose Prospective investigation of incidence and outcome of occipital condyle fractures (OCF) in a level 1 trauma centre. Methods Over a period of 5 years, we prospectively recorded all cases of OCF, and performed a 1-year postinjury radiological and clinical follow-up using CT imaging, SF-36 and Neck Disability Index, respectively. Results A total of 31 patients with OCF were identified. Based on a total of 2,616 CT scans that had been performed during this period, the incidence was 1.19%. There were 27 unilateral and 4 bilateral OCFs. Furthermore, 3 out of 31 patients (9.7%) were additionally diagnosed with atlantooccipital dislocation (AOD), one of which was dorsally stabilised in a surgical procedure. All other patients were treated conservatively. 5 out of 31 patients (16.1%) died due to the severity of associated injuries. 22 out of 31 patients (70.9%) were prospectively followed-up for 1 year after trauma. During this period, CT imaging showed bony consolidation of fractures in all cases except for one, with no evidence of secondary dislocation or nonunion. Evaluation of the Neck Disability Index showed moderate disability. The SF-36 questionnaire showed an impaired quality of life in all areas; however, these were determined by associated injuries and independent of the type of fracture. Conclusions Both unilateral and bilateral OCFs represent a stable injury regardless of the type of fracture. If AOD has been diagnosed in addition, it requires surgical stabilisation-independent of the OCF-and it is a significant predictor for poor outcomes. The patients quality of life 1 year after trauma has not been affected by the OCF, but by the overall pattern of the injury and by comorbidities. Based on our results, we introduce a new, simple and practical classification for OCFs.
Background Open reduction and stabilization of dorsal pelvic ring injuries is accompanied by a high rate of soft tissue complications. Minimally invasive techniques have the potential to decrease soft tissue trauma, but the risk of iatrogenic nerve and vessel damage through the reduced surgical exposure should be considered. We treated these injuries using a transiliac internal fixator (TIFI) in a minimally invasive technique characterized by implantation of a pedicle screw and rod system, bridging the sacroiliac joints and the sacral area. Questions/purposes We asked whether (1) we could achieve anatomic restoration with the device, (2) specific complications were associated with this minimally invasive approach (particularly enhanced intraoperative blood loss, soft tissue complications, and iatrogenic neurovascular damage), and (3) function 3 years after trauma was comparable to that of established methods. Methods We retrospectively reviewed 67 patients with dorsal pelvic injuries during a 7-year period. We evaluated the (1) reduction by grading the maximal displacement measured with three radiographic views, (2) the complications during the observation period, and (3) the function with a validated questionnaire (Pelvic Outcome Score) in all but five patients at least 3 years after trauma (mean, 37 months; range, 36-42 months). Results At last followup we observed a secondary fracture displacement greater than 5 mm in one patient. The intraoperative blood loss was less than 50 mL in all patients. No neurovascular lesions occurred owing to implantation. Four patients had wound infections, one had loosening of a single pedicle screw, and one had an iatrogenic screw malpositioning. Thirty-five of the 62 patients achieved Pelvic Outcome Scores of either a maximum score or 6 of 7 points. Conclusion Our observations suggest TIFI is a reasonable alternative to other established fixation devices for injuries of the dorsal pelvic ring with minor risks of major blood loss or iatrogenic neurovascular damage.
Background Prospective evaluation of atlanto-occipital dissociations (AODs) at a level 1 trauma centre within 5 years. Methods Over a period of 5 years (2005)(2006)(2007)(2008)(2009), all CT scans of the skull base and the upper cervical spine due to traumatic injuries were prospectively entered into a database. Furthermore, in cases of confirmed AOD all empirical data were prospectively collected. A more detailed data analysis of all AOD patients was conducted 2 years post-trauma. If required, another prospective follow-up was performed. Results 2,616 CT scans were performed in total. Out of these, there were five male patients with confirmed AOD. Thus, the total incidence was 0.2 %. AOD was associated with occipital condyle fractures in three out of the five cases. Three out of five patients (60 %) died due to the severity of the injury. It was possible to stabilise two patients surgically with a clinical/radiological follow-up 2 years post-surgery. At that time, one patient had an incomplete tetraplegia and was wheelchair ridden without needing ventilation, while the other patient suffered from post-traumatic stress disorder, but was able to walk and live alone. Conclusions AOD is a rarely seen injury, even in a level 1 trauma centre, and is associated with high morbidity and mortality. However, it is possible for adults to survive this severe occipito-cervical injury after surgical repair while maintaining the ability to walk. All the results and recommendations are still based on a low level of evidence, due to the low incidence of this injury.
Purpose We evaluated the biomechanical characteristics of the transiliac internal fixator (TIFI) as compared to two wellestablished methods of internal posterior pelvic ring fixation. Methods Six freshly frozen human pelves were used for simulated single-leg stance loading of an AO type C injury model (pubic symphysis diastasis and unilateral sacroiliac joint disruption). The symphysis rupture was stabilized with a dynamic compression plate. Afterwards the three internal stabilization systems (TIFI, iliosacral screws and ventral plate osteosynthesis) were analysed. Fragment movement was measured in a contact-free manner with a stereophotometric infrared system. Results No significant differences in the three-dimensional deformation tolerated by the TIFI as compared to the other internal fixation systems were found. Conclusions The transiliac internal fixator provides the same biomechanical stability as the other reference implants tested. We suggest the use of this device as a suitable alternative to the other implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.