In this work, two practical methods for the measurement of signal-to-noise-ratio (SNR) performance in parallel imaging are described. Phantoms and human studies were performed with a 32-channel cardiac coil in the context of ultrafast cardiac CINE imaging at 1.5 T using steady-state free precession (SSFP) and TSENSE. SNR and g-factor phantom measurements using a "multiple acquisition" method were compared to measurements from a "difference method". Excellent agreement was seen between the two methods, and the g-factor shows qualitative agreement with theoretical predictions from the literature. Examples of high temporal (42.6 ms) and spatial (2.1 ؋ 2.1 ؋ 8 mm 3 ) resolution cardiac CINE SSFP images acquired from human volunteers using TSENSE are shown for acceleration factors up to 7. Image quality agrees qualitatively with phantom SNR measurements, suggesting an optimum acceleration of 4. With this acceleration, a cardiac function study consisting of 6 image planes (3 short-axis views, 3 long-axis views) was obtained in an 18-heartbeat breath-hold. Magn Reson Med 54:748 -754, 2005.
The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.
In clinical routine, coronary CTA will primarily be used for risk stratification on a per patient basis. In the present study, coronary 64-MDCT showed a high diagnostic accuracy on both per patient and per segment analyses.
Granulocyte colony-stimulating factor treatment after PCI in subacute STEMI is feasible and relatively safe. However, patients do not benefit from G-CSF when PCI is performed late. Granulocyte colony-stimulating factor results in improved myocardial perfusion of the infarcted area, which may reflect enhanced neovascularization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.