High brightness, chemical and photostability, tunable characteristics, and spectral and surface properties are important attributes for nanoparticle probes designed for live cell imaging. We describe a class of nanoparticles for high-resolution imaging of O2 that consists of a substituted conjugated polymer (polyfluorene or poly(fluorene-alt-benzothiadiazole)) acting as a FRET antenna and a fluorescent reference with covalently bound phosphorescent metalloporphyrin (PtTFPP, PtTPTBPF). The nanoparticles prepared from such copolymers by precipitation method display stability, enhanced (>5-10 times) brightness under one- and two-photon excitation, compatibility with ratiometric and lifetime-based imaging modes, and low toxicity for cells. Their cell-staining properties can be modulated with positively and negatively charged groups grafted to the backbone. The "zwitter-ionic" nanoparticles show high cell-staining efficiency, while their cell entry mechanisms differ for the different 3D models. When injected in the bloodstream, the cationic and anionic nanoparticles show similar distribution in vivo. These features and tunable properties make the conjugated polymer based phosphorescent nanoparticles a versatile tool for quantitative O2 imaging with a broad range of cell and 3D tissue models.
Knowledge on the availability of dissolved oxygen inside microfluidic cell culture systems is vital for recreating physiological-relevant microenvironments and for providing reliable and reproducible measurement conditions. It is important to highlight that in vivo cells experience a diverse range of oxygen tensions depending on the resident tissue type, which can also be recreated in vitro using specialized cell culture instruments that regulate external oxygen concentrations. While cell-culture conditions can be readily adjusted using state-of-the-art incubators, the control of physiological-relevant microenvironments within the microfluidic chip, however, requires the integration of oxygen sensors. Although several sensing approaches have been reported to monitor oxygen levels in the presence of cell monolayers, oxygen demands of microfluidic three-dimensional (3D)-cell cultures and spatio-temporal variations of oxygen concentrations inside two-dimensional (2D) and 3D cell culture systems are still largely unknown. To gain a better understanding on available oxygen levels inside organ-on-a-chip systems, we have therefore developed two different microfluidic devices containing embedded sensor arrays to monitor local oxygen levels to investigate (i) oxygen consumption rates of 2D and 3D hydrogel-based cell cultures, (ii) the establishment of oxygen gradients within cell culture chambers, and (iii) influence of microfluidic material (e.g., gas tight vs. gas permeable), surface coatings, cell densities, and medium flow rate on the respiratory activities of four different cell types. We demonstrate how dynamic control of cyclic normoxic-hypoxic cell microenvironments can be readily accomplished using programmable flow profiles employing both gas-impermeable and gas-permeable microfluidic biochips.
Optical sensing materials for the selective measurement of potassium ions (K+) in water are presented. The indicator dyes are based on an aza‐crown ether as a receptor and borondipyrromethenes (BODIPY) dyes as fluorophores. Fluorescence enhancement is caused by the reduction of photoinduced electron transfer (PET) upon complexation with K+ ions. The family of new indicators possesses tuneable optical properties (green to red excitation, red to NIR emission) and PET efficiencies. They exhibit high brightness with quantum yields between 0.20 and 0.47 in the “on” state and a molar absorption coefficient between 30 000 and 290 000 m−1 cm−1. The new indicator dyes are immobilized in biocompatible hydrogel matrices to obtain stable nonleaching and fast responding (t90 ≈ 10 s) sensing materials for continuous measurements of potassium. They are realized in various formats such as planar optodes, fiber‐optic sensors, and water‐dispersible polymer‐based nanoparticles. Apart from fluorescence intensity measurements, self‐referenced read‐out of fluorescence decay time is demonstrated. All sensor materials display a high K+/Na+ selectivity and are not influenced by pH within the physiologically relevant range. Practical applicability of the materials is emphasized by application of a fiber‐optic sensor to quantification of K+ in serum, which shows excellent correlation with the reference measurements.
New high performance optical oxygen sensing materials based on NIR-emitting indicators covalently bound to various polymers overcome main limitations of the conventional sensors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.