Respiratory syncytial virus (RSV) usually causes self-limiting upper respiratory tract infections, but can be associated with severe lower respiratory tract infection disease (LRTID) in infants and in patients with hematologic malignancies. We have analyzed the risk factors and the measures for containment within an outbreak of nosocomial RSV infections in a hematology and SCT unit. A total of 56 patients were affected (53 RSV-A and 3 RSV-B) including 32 transplant patients (16 allogeneic and 16 autologous). Forty (71%) of the 56 patients suffered from LRTID and 14 (35%) of the patients with LRTID subsequently died. However, because of concomitant infections with fungal and bacterial pathogens, the impact of RSV on the fatal outcome was difficult to assess. Multivariate analysis showed that low levels of IgG were significantly associated with fatal outcome (P ¼ 0.007), treatment with oral ribavirin represented a protective factor (P ¼ 0.02). An extremely protracted viral shedding was observed in this cohort of patients (median ¼ 30.5 days, range: 1-162 days), especially pronounced in patients after allogeneic transplantation (P ¼ 0.002). Implementation of rigorous isolation and barrier measures, although challenged by long-term viral carriers, was effective in containment of the outbreak.
The aim of this multicenter study was to evaluate the technical and clinical performance of the Elecsys S100 electrochemiluminescence immunoassay and to assess its utility as a tumor marker in patients with malignant melanoma. Imprecision studies yielded within-run coefficients of variation (CVs) of 0.7-2.0% and between-day CVs of 1.0-6.4%. Serum samples that were distributed to 11 participating laboratories for a comparability analysis resulted in excellent recoveries of 93-105% related to the median for all laboratories. The functional sensitivity of the assay was determined to be below 0.02 microg/L. The lot-to-lot reproducibility of Elecsys S100 was tested by analyzing 110 sera with three different reagent lots on an E2010 analyzer. This lot-to-lot comparison showed excellent correlation, with a coefficient of 0.99. A 95th percentile cut-off value of 0.10 microg/L was calculated from values measured in 206 healthy individuals. Using this cut-off value, sensitivity of 41% was found, with positive and negative predictive values of 0.50 and 0.91, respectively. Method comparison with the Sangtec 100 luminescence immunoassay, run on two different analyzers, showed correlation with coefficients ranging from 0.76 to 0.95. A comparison of S100 values obtained with both tests showed identical patterns in 68 serial samples from 15 patients with malignant melanoma during follow-up. These findings indicate that serial measurements with the Elecsys S100 assay are useful for the follow-up and monitoring of therapy in patients with malignant melanoma.
Community-acquired pneumonia is a common disease of the elderly and involves a high mortality risk. Demographic developments are creating new challenges for acute medical treatment strategies in geriatric patients with their underlying multimorbidity. In addition to the diagnostic parameters recorded on hospital admission, such as white cell count and C-reactive protein, procalcitonin, more than the risk scores CRB- and CURB-65 evaluated to date, appears to be a promising parameter for assessing the severity of pneumonia in elderly patients to allow early detection of severe courses and initiation of suitable treatment. The decisive factor is the dynamic course of the procalcitonin values over 3 consecutive days, as demonstrated in this case series.
Autoimmune disorders are rare human diseases characterized by the presence of circulating autoantibodies that bind the body's own structural compounds as target antigens. The detection of autoantibodies is important for the diagnostic process. Immunofluorescence and immunoassay methods do not allow a reliable characterization of binding characteristics. Therefore, novel analytical techniques should be considered. This review describes the application of surface plasmon resonance biosensor systems for the diagnosis of autoimmune disorders. The covalent attachment of native antigens to the sensor chip is a suitable method for obtaining highly reproducible analyses of autoantibodies, allowing the evaluation of kinetic rate and affinity constants, and it may enable the identification of disease-relevant autoantibodies linked to disease progression. The autoantibody microarray is another future-oriented technique. Patterns of differential antigen recognition should allow early diagnosis. This is due to the fact that a broad range of autoreactive B cell responses in autoimmune disorders can only be mirrored by including a sufficient number of antigens in a microarray format.
In patients with known PAOD, a combined static and dynamic CTA examination improves image quality relative to static and dynamic MRA and should be considered as an alternative to MRA, particularly in patients with advanced stage PAOD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.