Centrifugal pumps are considered to be less destructive to blood elements(1) when compared to roller pumps. However, their large prime volumes render them unsuitable as arterial pumps in heart lung machine (HLM) circuitry for children. In November of 2014, the circuit at Arnold Palmer Hospital, a Biomedicus BP-50 with kinetic assist venous drainage (KAVD) and 1/4″ tubing was converted to a roller pump in the arterial position with gravity drainage. Vacuum-assisted venous drainage (VAVD) was mounted on the HLM as a backup, but not used. Tubing was changed to 3/16″ in the arterial line in patients <13 kg. A retrospective study with a total of 140 patients compared patients placed on cardiopulmonary bypass (CPB) with Biomedicus centrifugal pumps and KAVD (Centrifugal Group, n = 40) to those placed on CPB with roller pumps and gravity drainage (Roller Group, n = 100). Patients requiring extra-corporeal membrane oxygenation (ECMO)/cardio-pulmonary support (CPS) or undergoing a hybrid procedure were excluded. Re-operation or circulatory arrest patients were not excluded. Prime volumes decreased by 57% from 456 ± 34 mL in the Centrifugal Group to 197 ± 34 mL in the Roller Group (p < .001). There was a corresponding increase in hematocrit (HCT) of blood primes and also on CPB. Intraoperative homologous blood transfusions also decreased 55% from 422 mL in the Centrifugal Group to 231 mL in the Roller Group (p < .001). The Society of Thoracic Surgeons--European Association for Cardio-Thoracic Surgery (STAT) categorized intubation times and hospital length of stay (LOS) for all infants showed a trend toward reduction, but was not statistically significant. Overall mortality was 5% utilizing the centrifugal configuration and 0% in the roller pump cohort. We demonstrated that the transition to roller pumps in the arterial position of the HLM considerably reduced our priming volume and formed a basis for a comprehensive blood conservation program. By maintaining higher HCTs on CPB, we were able to reduce intraoperative homologous blood transfusions.
The 1/2″ venous line has long been the drainage tubing diameter of choice for adult patients undergoing cardiac surgery. However, several programs use a smaller diameter venous line when used in conjunction with kinetic-assisted venous drainage or vacuum-assisted venous drainage. In 2014, our perfusion team made an institution-wide effort to miniaturize the cardiopulmonary bypass (CPB) circuit for children. One of our changes was the transition to a 3/8″ diameter venous line for drainage, even in our larger patients (up to 80 kg). We reviewed the current literature on this topic and delineated the various parameters required to be able to use the 3/8″ venous line with gravity drainage with the aim of using it on patients up to 115 kg with the appropriate venous reservoir. We have successfully used the 3/8″ venous line in more than 40 of our larger patients (35–90 kg) without the need for assisted venous drainage. We were able to reduce CPB prime from 625 ± 118 to 425 ± 52 mL before retrograde autologous priming (RAP)/venous autologous priming (VAP). The prime was further reduced to 325 ± 66 mL after RAP/VAP. Homologous blood utilization was reduced from 217 ± 311 mL to 27 ± 77 mL. Both results were statistically significant. We hypothesize that taking into account two of the parameters of Poiseuille’s law, namely length and diameter, it is possible to safely drain large children and mid-size adults via gravity venous drainage and the 3/8″ venous line. This technique allows reducing prime volume, simplifies CPB circuits with increased safety and potentially reduces the need for homologous blood transfusion.
Transthoracic intra-aortic balloon pump (IABP) insertion has been a relatively rare and uncommon procedure. However, it is an established beneficial option in patients with severe peripheral vascular disease (PVD) accompanied with bi-lateral femoral arterial occlusion. There are several viable alternatives to trans-aortic IABP insertion, including trans-axillary or in abdominal aorta (requiring a laparotomy). Cardiac surgery has the advantage of an open sternum, facilitating effortless direct intraaortic balloon (IAB) insertion into the aorta. The IAB can be inserted either through a 9-mm graft or directly into the ascending aorta. During cardiac surgery, direct insertion into the ascending aorta with the balloon tip lying distally in the abdominal aorta is facilitated with an open sternum. The base of the balloon lies ∼2 cm below the left subclavian and can be confirmed through a trans-esophageal echocardiogram (TEE). Elimination of a graft insertion saves the team from time-consuming maneuvers and additional hemorrhagic complications. In our experience, postoperative vasoplegic syndrome coupled with myocardial edema contributed to patent instability and was treated with vasopressin and transthoracic IAB insertion. The CS 100 (Datascope Corp., Mahwah, NJ) console allowed the ability to time the balloon accurately. This case report details our experience with one such patient and establishes trans-aortic counter-pulsation as a safe and viable option in patients with severe PVD, where percutaneous insertion is precluded or has failed.
Modified ultrafiltration (MUF) is used in neonates and infants to reduce volume overload and increase oxygen-carrying capacity post cardiopulmonary bypass (CPB). In addition, it decreases edema, attenuates complementation activation and immunogenic response to CPB. Hemodilution in the pediatric patient has always been a challenge, countered in part by miniaturization of CPB circuits. We describe a case in which we maintained an acceptable hematocrit level greater than 24%, considered the nadir below which the adverse effects of hemodilution can become evident. We performed this by the novel use of an intravenous warming device (enFlow, Vyaire Medical, Mettawa, IL) to reduce the prime volume of our MUF circuit by more than 50%. We present the case and discuss the advantages and disadvantages of using a low-prime MUF circuit. We were able to conduct “bloodless” CPB, with the use of acute normovolemic hemodilution, miniaturization of the CPB and MUF circuits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.