One of the commonest treatment options for replacing missing teeth is a root-form implant. Clinically, the key mechanical factor in achieving success is primary stability. This ex vivo study aims to evaluate whether osseodensification method will achieve good primary stability or the conventional drilling protocol. MethodsFresh iliac bone of the sheep was selected similar to D3 and D4 bone densities. A total of 22 osteotomy sites were prepared in the bone sample, of which 11 were prepared by osseodensification method (test group) and other 11 by conventional undersized drilling (control group). Primary stability was measured using insertion torque (IT), resonance frequency analysis (RFA), and reverse torque values (RTVs) by measuring implant stability quotient (ISQ). The recorded data were statistically analyzed using Statistical Package for the Social Sciences (SPSS) Version 22.0. The differences between groups were compared using the Mann-Whitney U test and independent t-test. The Pearson correlation coefficient test was performed to measure the linear relationship between two variables. The statistical significance level was established at p<0.05. ResultsWhen the correlation among IT, RTV, and ISQ was measured, a statistically significant correlation between IT and RTV (p=0.001) and between IT and ISQ (p=0.0001) was observed. A statistically significant (p=0.014) correlation between RTV and ISQ was also found. ConclusionOsteotomy prepared by osseodensification method showed higher IT, RTV, and ISQ values than the conventional undersized group.
To evaluate the better method of implant insertion into the osteotomy site in compromised quality bone for attaining optimal primary stability and thereby achieving the osseointegration for the ultimate success of implant. A total of 32 specimens (wood blocks) simulating D4 bone, were categorized into two groups. The osteotomy site was prepared as per the protocol and implants were placed till the level of the block. The insertion torque was quantified using digital Kratos torque meter. While the implants were inserted and abutments placed by hand ratcheting in the first group; they were motor-driven in the second group. Later pullout test was carried out in universal testing machine and results were analyzed using IBM SPSS Statistics for Windows Software, version 22 (IBM Corp., Armonk, NY, USA). The mean pull out force values obtained in implants placed by hand driven method were 624.375 N while the force values for implants inserted by motor-driven was 692.625 N. There was a statistically significant difference between hand and motor driven implant into the osteotomy site (p<0.05) between the groups. Of the different methods of implant insertion evaluated in this study, motor-driven imply to have a better primary stability indicating better integration with the bone to become a successful implant.
A BSTRACT Objective: The purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. Materials and Methods: A total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance. Results: An intergroup comparison of peak loads revealed an overall statistically significant difference ( P < 0.0001) with a mean of 442.638 N, maximum in group 4 and least (202.963 N) in group 1. The mean elongation break was found to be maximum in group 3 samples (81.67600%) and less in group 4 (37.15113%). Intergroup comparison of Young’s modulus was statistically significant ( P < 0.0001) with a mean value found to be minimum among group 1 samples (597.54750 MPa) and maximum in group 2 (1056.76463 MPa). An intergroup comparison of yield points was found to be maximum among group 4 samples (16.17238MPa) and least in group 1 (5.77438MPa). Conclusion: The D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually.
In today's restorative dentistry, replacement of missing tooth/teeth with implants has evolved as the most reliable and challenging eld through spectacular innovations with proven success. With the advent of tissue engineering, the outlook of implant dentistry has transformed especially with periodontal tissues. 'Ligaplants' unlike traditional implants have recently been introduced to address the shortcomings of conventional implants. Though there are pitfalls, future seems to be more promising with ligaplants that could revolutionize implant dentistry to a greater extent
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.