The method for preconcentration and trace determination of Hg(II) based on the total fluorescence quenching using a 1,10-phenanthroline (1,10-phen) and dichlorofluorescein (DCF) ternary complex after homogeneous liquid-liquid extraction of the metal complex was developed. Hg(II) ions were dissolved in acid and the sample was complexed with an excess amount of diethyldithiocarbamate (DDTC).The complex of Hg(II)-DDTC formed in an aqueous phase and was extracted into a layer of perfluorooctanoic acid dissolved in lithium hydroxide solution, resulting in $100 mL of the sediment liquid phase prior to analysis of the ternary complex by spectrofluorophotometry. The optimization conditions were investigated in detail including pH and buffer solution, type of ligand, ionic strength, counter ion and micellar medium. Under the optimized conditions with a preconcentration factor between 15 and 20 using a mixture of 0.2 mol L À1 acetate buffer pH 4.5, 2.5 Â 10 À3 mol L À1 1,10-phen, 1% (v/v) Triton X-100 and 2.9 Â 10 À6 mol L À1 DCF in 15 mL final volume, the decrease in fluorescence intensity of the ternary complex was measured against the reagent blank, in the absence of Hg(II) ions, at the excitation and emission wavelengths of 504.0 and 525.0 nm, respectively. The calibration curve was widely linear over the range of 4.0 mg L À1 to 2.0 mg L À1 with a correlation coefficient greater than 0.997. The method recovery of Hg(II) was about 76.9 to 98.2% at a concentration of 250 mg L À1 . The relative standard deviation (RSD) was below 5.5% with a detection limit of 1.0 mg L À1 . The proposed method was successfully applied for the determination of Hg(II) in drinking water, distilled spirit and fruit wine samples. The results obtained were in agreement with those of FI-HGAAS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.