Transthoracic electrical bioimpedance (TEB) has been proposed as a non-invasive, continuous, and cost-effective method of cardiac output (CO) measurement. In this prospective, non-randomized, clinical study, we measured CO with NICOMON (Larsen and Toubro Ltd., Mysore, India) and compared it with thermodilution (TD) method in patients after off-pump coronary artery bypass (OPCAB) graft surgery. We also evaluated the effect of ventilation (mechanical and spontaneous) on the measurement of CO by the two methods. Forty-six post-OPCAB patients were studied at five predefined time points during controlled ventilation and at five time points when breathing spontaneously. A total of 230 data pairs of CO were obtained. During controlled ventilation, TD CO values ranged from 2.29 to 6.74 L/min (mean 4.45 ± 0.85 L/min), while TEB CO values ranged from 1.70 to 6.90 L/min (mean 4.43 ± 0.94 L/min). The average correlation (r) was 0.548 (P = 0.0002), accompanied by a bias of 0.015 L/min and precision of 0.859 L/min. In spontaneously breathing patients, TD CO values ranged from 2.66 to 6.92 L/min (mean 4.66 ± 0.76 L/min), while TEB CO values ranged from 3.08 to 6.90 L/min (mean 4.72 ± 0.82 L/min). Their average correlation was relatively poor (r = 0.469, P= 0.002), accompanied by a bias of -0.059 L/min and precision of 0.818 L/min. The overall percent errors between TD CO and TEB CO were 19.3% (during controlled ventilation) and 17.4% (during spontaneous breathing), respectively. To conclude, a fair correlation was found between TD CO and TEB CO measurements among post-OPCAB patients during controlled ventilation. However, the correlation was weak in spontaneously breathing patients.
Sudden cardiac arrest (SCA) in children is a rare, but catastrophic event. Children with cardiac pathology at particular risk include those with congenital long QT syndrome (CLQTS) and hypertrophic cardiomyopathy. CLQTS is a genetic disorder of the cardiac ion channels and is associated with significant risk of malignant ventricular arrhythmias and SCA. For symptomatic, untreated patients, the mortality rate is approximately 20% for the first year and 50% at ten years. Use of an implantable cardioverter-defibrillator (ICD) is recommended for the prevention of SCA in this patient population. We report a case of CLQTS, who after successful resuscitation from SCA, underwent ICD placement at our center.
Valvular heart disease in systemic lupus erythematosus (SLE) is associated with substantial morbidity and mortality. Current therapy includes symptomatic measures and valve replacement. SLE can present major challenges because of accrued organ damage, coagulation defects and complex management regimes. The peri-operative goals are to maintain strict asepsis, avoid use of nephrotoxic drugs and thereby renal insult, and to promote early ambulation post-operatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.