We assessed the utility of synchrotron-radiation micro-computed tomography (micro-CT) for quantification of the radial geometry of the renal cortical vasculature. The kidneys of nine rats and six rabbits were perfusion fixed and the renal circulation filled with Microfil. In order to assess shrinkage of Microfil, rat kidneys were imaged at the Australian Synchrotron immediately upon tissue preparation and then post fixed in paraformaldehyde and reimaged 24 hours later. The Microfil shrank only 2-5% over the 24 hour period. All subsequent micro-CT imaging was completed within 24 hours of sample preparation. After micro-CT imaging, the kidneys were processed for histological analysis. In both rat and rabbit kidneys, vascular structures identified in histological sections could be identified in two-dimensional (2D) micro-CT images from the original kidney. Vascular morphology was similar in the two sets of images. Radial geometry quantified by manual analysis of 2D images from micro-CT was consistent with corresponding data generated by light microscopy. However, due to limited spatial resolution when imaging a whole organ using contrast-enhanced micro-CT, only arteries ≥100 and ≥60 μm in diameter, for the rat and rabbit respectively, could be assessed. We conclude that it is feasible and valid to use micro-CT to quantify vascular geometry of the renal cortical circulation in both the rat and rabbit. However, a combination of light microscopic and micro-CT approaches are required to evaluate the spatial relationships between intrarenal arteries and veins over an extensive range of vessel size.
Vascular topology and morphology are critical in the regulation of blood flow and the transport of small solutes, including oxygen, carbon dioxide, nitric oxide, and hydrogen sulfide. Renal vascular morphology is particularly challenging, since many arterial walls are partially wrapped by the walls of veins. In the absence of a precise characterization of three-dimensional branching vascular geometry, accurate computational modeling of the intrarenal transport of small diffusible molecules is impossible. An enormous manual effort was required to achieve a relatively precise characterization of rat renal vascular geometry, highlighting the need for an automated method for analysis of branched vasculature morphology to allow characterization of the renal vascular geometry of other species, including humans. We present a semisupervised method for three-dimensional morphometric analysis of renal vasculature images generated by computed tomography. We derive quantitative vascular attributes important to mass transport between arteries, veins, and the renal tissue and present methods for their computation for a three-dimensional vascular geometry. To validate the algorithm, we compare automated vascular estimates with subjective manual measurements for a portion of rabbit kidney. Although increased image resolution can improve outcomes, our results demonstrate that the method can quantify the morphological characteristics of artery-vein pairs, comparing favorably with manual measurements. Similar to the rat, we show that rabbit artery-vein pairs become less intimate along the course of the renal vasculature, but the total wrapped mass transfer coefficient increases and then decreases. This new method will facilitate new quantitative physiological models describing the transport of small molecules within the kidney.
Diffusion tensor imaging (DTI) is an MRI technique that can be used to map cardiomyocyte tracts and estimate local cardiomyocyte and sheetlet orientation within the heart. DTI measures diffusion distances of water molecules within the myocardium, where water diffusion generally occurs more freely along the long axis of cardiomyocytes and within the extracellular matrix, but is restricted by cell membranes such that transverse diffusion is limited. DTI can be undertaken in fixed hearts and it allows the three‐dimensional mapping of the cardiac microarchitecture, including cardiomyocyte organization, within the whole heart. The objective of this study was to use DTI to compare the cardiac microarchitecture and cardiomyocyte organization in archived fixed left ventricles of lambs that were born either preterm (n = 5) or at term (n = 7), at a postnatal timepoint equivalent to about 6 years of age in children. Although the findings support the feasibility of retrospective DTI scanning of fixed hearts, several hearts were excluded from DTI analysis because of poor scan quality, such as ghosting artifacts. The preliminary findings from viable DTI scans (n = 3/group) suggest that the extracellular compartment is altered and that there is an immature microstructural phenotype early in postnatal life in the LV of lambs born preterm. Our findings support a potential time‐efficient imaging role for DTI in detecting abnormal changes in the microstructure of fixed hearts of former‐preterm neonates, although further investigation into factors that affect scan quality is required.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.