Over the past few decades, numerous studies have explored the use of steel fiber (SF) as an alternative to transverse reinforcement rebars in reinforced concrete beams, either partially or completely replacing them. However, there are limited studies that have investigated the effect of fiber dosage and length on reinforced concrete beam performance under torsional loads without the use of transverse reinforcement rebars. In this study, experimental investigations were conducted to examine the performance of reinforced SF concrete beams subjected to torsional load, utilizing SFs as a complete substitution of transverse reinforcement rebars. Ten different concrete mixes with varying dosages of SFs, namely 0%, 0.5%, 1.0%, and 1.5%, were examined while maintaining the same aspect ratio for fiber length and diameter. The results revealed that the addition of SFs in the concrete mix had an impact on its properties, reducing workability but increasing flexural, tensile, and compressive strengths. By incorporating 1.0% of SFs in the concrete mix, the missing torsional strength resulting from the absence of stirrups was adequately compensated. Moreover, the presence of SFs significantly influenced the ductile behavior beyond the point of cracking in the tested beams. Hence, it is recommended that SFs are incorporated with dosages of 1.0% and 1.5% in the concrete mixture, particularly for beams subjected to torsion, as a viable substitute for stirrups.
Reinforced concrete two-way flat slabs are considered one of the most used systems in the construction of commercial buildings due to the ease of construction and suitability for electrical and mechanical paths. Long-term deflection is an essential parameter in controlling the behavior of this slab system, especially with long spans. Therefore, this study is devoted to investigating the validation of the ACI 318-19 Code long-term deflection limitations of a wide range of span lengths of two-way flat slabs with and without drop panels. The first part of the study includes nonlinear finite element analysis of 63 flat slabs without drops and 63 flat slabs with drops using the SAFE commercial software. The investigated parameters consist of the span length (4, 5, 6, 7, 8, 9, and 10m), compressive strength of concrete (21, 35, and 49 MPa), the magnitude of live load (1.5, 3, and 4.5 kN/m2), and the drop thickness (0.25tslab, 0.5tslab, and 0.75tslab). In addition, the maximum crack width at the top and bottom are determined and compared with the limitations of the ACI 224R-08. The second part of this research proposes modifications to the minimum slab thickness that satisfy the permissible deflection. It was found, for flat slabs without drops, the increase in concrete compressive strength from 21MPa to 49MPa decreases the average long-term deflection by (56, 53, 50, 44, 39, 33 and 31%) for spans (4, 5, 6, 7, 8, 9, and 10 m) respectively. In flat slab with drop panel, it was found that varying drop panel thickness t2 from 0.25 to 0.75 decreases the average long-term deflection by (45, 41, 39, 35, 31, 28 and 25%) for span lengths (4, 5, 6, 7, 8, 9 and 10 m) respectively. Limitations of the minimum thickness of flat slab were proposed to vary from Ln/30 to Ln/19.9 for a flat slab without a drop panel and from Ln/33 to Ln/21.2 for a flat slab with drop panel. These limitations demonstrated high consistency with the results of Scanlon and Lee's unified equation for determining the minimum thickness of slab with and without drop panels. Doi: 10.28991/cej-2021-03091769 Full Text: PDF
The flexural strength of slabs may be reduced due to accidents and environmental effects. This study focuses on the rehabilitation of the one-way reinforced concrete slab. Experimental works include five simply supported one-way reinforced concrete slabs with width, depth, and length of 400, 120, and 2200 mm, respectively. Different configurations of steel continuity between old and new concrete have been tested. Moreover, in the control specimen (steel is continued overall, the specimen and concrete are cast in one stage over the entire slab). In the other four specimens, the concrete is cast in two stages, the left and right parts representing the old concrete are cast first, and the middle part representing a new concrete is cast after that. In these four specimens, new steel is connected to old one by different configuration (original steel remain to continue, new steel connected to old one by weld, new steel connected to old one by making 90° hooks, and new steel bars is put inside bores using epoxy). After testing, the welding method of connecting new to old steel is the best one.
The concrete cover is a part of the concrete that provides the required protection for the reinforcing steel within the required element from external effects. This concrete cover can be damaged for an assortment of reasons, one of which is environmental factors. As a result, this research focused on the effect of worn concrete covering on the structural response of beams. Moreover, the possibility of repairing or replacing this concrete cover with a cement material was done by testing seven beams with the exact dimensions (2700 mm long, 250 mm deep, and 140 mm wide). The first specimen was a control specimen, while in the remaining specimens, a part of the concrete cover was removed in the midspan region with a length of 600 mm and in different formats. The part below the neutral axis (tension zone) was removed in the first two specimens. The part above the neutral axis (the compression zone) was removed in the second two specimens. The whole cover was removed within the specified distance for the other two specimens. In one out of every two of these six specimens, the removed concrete cover was replaced with cementitious material. A flexural test was performed for all specimens, and the conclusion was reached that damaging or removing the concrete cover from the tensile region (below the neutral axis) is less harmful than from the compression region since the beam is often designed as a cracked section. Also, removing the concrete cover from the compression region gives cracks a greater width than removing the concrete cover from the tension region at the same loading level. In the case of replacing the concrete cover with a cementitious one, if the replacement is in the compression zone, it will result in cracks when loading with a width greater than that of the rest of the cases. For specimens that removed their concrete covers from the tension zone, compression zone, and the whole section, the failure loads decreased by 39%, 20%, and 23%, respectively, concerning the control beam. In contrast, all these specimens were repaired with cementitious materials, with an ultimate load capacity approximately equal to the control beams. From these results, any damaged concrete cover for beams in any zone with cementitious materials having high strength and a good bond with old concrete sections can be repaired. Doi: 10.28991/CEJ-2023-09-07-09 Full Text: PDF
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.