Purpose: Recently developed implantable microdevices can perform multi-drug response assessment of cancer drugs in-vivo, with potential to develop highly optimized personalized cancer treatment strategies. However, minimally invasive/interventional image-guided methods of in-vivo microdevice implantation, securement, and retrieval are needed for broad clinical translation. Here we demonstrate proof-of-concept of an interventional microdevice implantation and retrieval method for personalized drug response assessment, using ex-vivo phantom, ex-vivo tissue, and in-vivo murine models. Methods: A method for minimally-invasive microdevice implantation and retrieval was developed, by which a custom-prototyped 6 mm retrievable microdevice can be implanted into a live tumor, deliver drugs into 10 discrete regions of adjacent tissue, and retrieved along with the adjacent drug-exposed tissue with a custom-prototyped retrieval needle device to allow in-vivo multidrug response assessment. Computed tomography (CT) and ultrasound (US)-guided minimally invasive microdevice implantation and retrieval were tested in ex-vivo phantom and tissue models. Successful retrieval was defined as retrieval of the microdevice and adjacent core phantom/tissue sample containing at least 4/10 drug delivery sites. Subsequently, 10 implantation and retrieval trials in phantom models were performed using bi-axial and tri-axial retrieval needles; success rates were calculated and compared using a two-proportion z-test and the number of successfully retrieved drug release sites per microdevice was calculated and compared using a one-tailed independent t-test. Finally, five microdevices, each containing ten reservoirs preloaded with chemotherapy agent Doxorubicin, were implanted into mouse tumors in-vivo, secured for 24-h during drug release, and microdevice/tissue retrieval was performed under ultrasound guidance. Fluorescence microscopy of the retrieved tissue was used to confirm drug delivery and apoptosis staining assessed in-vivo tissue response; correlation of drug release and apoptosis staining were used to assess in-vivo drug efficacy. Results: Image-guided microdevice implantation and retrieval were successful in ex-vivo phantom and tissue models with both US and CT guidance. Bi-axial retrieval success rate was significantly higher than triaxial retrieval in ex-vivo phantom trials (90% vs 50%, z = 1.95, P = 0.026), and had nonsignificantly higher number of retrieved drug-release sites per microdevice (8.3 vs 7.0, t = 1.37, P = 0.097). Bi-axial retrieval was successful in all five in-vivo mouse tumor models, and allowed invivo drug response assessment at up to ten discrete drug delivery sites per microdevice. An average of 6.8/10 discrete tumor sites containing micro-doses of delivered drug were retrieved per in-vivo attempt (min 5, max 10, std 1.93). Tissue regions of drug delivery, as assessed with fluorescent Doxorubicin drug signal, correlated with regions of apoptosis staining in all in-vivo models, indicating drug efficacy. No bleeding,...
Tissue inhibitor of metalloproteinases-3 (TIMP-3) maintains a healthy extracellular matrix by regulating matrix metalloproteinases (MMP), disintegrin-metalloproteinases (ADAM), and disintegrin-metalloproteinases with ThromboSpondin-like motifs (ADAMTS) activity. Currently, there is a need for a comprehensive understanding of the effects of TIMP-3 on the bone quality and integrity. In this study, we examined the mechanical, morphological, and compositional properties of TIMP-3 knock out (Timp-3 ) mouse bone. We hypothesize that the lack of TIMP-3 plays an important role in maintaining the overall bone integrity. Mechanical properties of humeri, lumbar vertebrae, and femurs from Timp-3 mice were determined using 3-point bending, compression, and notched 3-point bending, respectively. Morphological properties of the humeral cortical and trabecular bone and the caudal vertebrae cortical bone were evaluated using micro-computed tomography, while the composition of the femoral cortical and trabecular bone was examined using Fourier transform infrared spectroscopic imaging. Our results revealed that the integrity of the Timp-3 bone is compromised due to changes in its composition, structure, and mechanics. Reductions in the yield and ultimate load and stress capacity, and loss in bone fracture toughness were attributed to reduced density and thickness, and increased porosity of cortical bone. Thin trabeculae were dense, highly connected, and closely packed in Timp-3 bone. Furthermore, altered cortical and trabecular bone mineralization and increased compositional heterogeneity were found in Timp-3 bone, all being indicative of high bone remodeling. In conclusion, this study suggests that the lack of TIMP-3 is detrimental to bone development and maintenance.
Abstract. Recent development of a novel micro-scale PV/CPV technology is presented. The Wafer Integrated Microscale PV approach (WPV) seamlessly integrates multijunction micro-cells with a multi-functional silicon platform that provides optical micro-concentration, hybrid photovoltaic, and mechanical micro-assembly. The wafer-embedded microconcentrating elements is shown to considerably improve the concentration-acceptance-angle product, potentially leading to dramatically reduced module materials and fabrication costs, sufficient angular tolerance for low-cost trackers, and an ultra-compact optical architecture, which makes the WPV module compatible with commercial flat panel infrastructures. The PV/CPV hybrid architecture further allows the collection of both direct and diffuse sunlight, thus extending the geographic and market domains for cost-effective PV system deployment. The WPV approach can potentially benefits from both the high performance of multijunction cells and the low cost of flat plate Si PV systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.