Sustainable development in the building sector requires the integration of energy efficiency and renewable energy utilization in buildings. In recent years, the concept of net zero energy buildings (NZEBs) has become a potential plausible solution to improve efficiency and reduce energy consumption in buildings. To achieve an NZEB goal, building systems and design strategies must be integrated and optimized based on local climatic conditions. This paper provides a comprehensive review of NZEBs and their current development in hot and humid regions. Through investigating 34 NZEB cases around the world, this study summarized NZEB key design strategies, technology choices and energy performance. The study found that passive design and technologies such as daylighting and natural ventilation are often adopted for NZEBs in hot and humid climates, together with other energy efficient and renewable energy technologies. Most NZEB cases demonstrated site annual energy consumption intensity less than 100 kW-hours (kWh) per square meter of floor space, and some buildings even achieved "net-positive energy" (that is, they generate more energy locally than they consume). However, the analysis also shows that not all NZEBs are energy efficient buildings, and buildings with ample renewable energy adoption can still achieve NZEB status even with high energy use intensity. This paper provides in-depth casestudy-driven analysis to evaluate NZEB energy performance and summarize best practices for high performance NZEBs. This review provides critical technical information as well as policy recommendations for net zero energy building development in hot and humid climates.
Based on comparative study on two amorphous silicon photovoltaic walls (a-Si PV walls), the temperature distribution and the instant power were tested; and with EnergyPlus software, similar models of the walls were built to simulate annual power generation and air conditioning load. On typical sunshine day, the corresponding position temperature of nonventilated PV wall was generally 0.5∼1.5 ∘ C higher than that of ventilated one, while the power generation was 0.2%∼0.4% lower, which was consistent with the simulation results with a difference of 0.41% in annual energy output. As simulation results, in summer, comparing the PV walls with normal wall, the heat per unit area of these two photovoltaic walls was 5.25 kWh/m 2 (nonventilated) and 0.67 kWh/m 2 (ventilated) higher, respectively. But in winter the heat loss of nonventilated one was smaller, while ventilated PV wall was similar to normal wall. To annual energy consumption of heating and cooling, the building with ventilated PV wall and normal wall was also similar but slightly better than nonventilated one. Therefore, it is inferred that, at low latitudes, such as Zhuhai, China, air gap ventilation is suitable, while the length to thickness ratio of the air gap needs to be taken into account.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.