A variety of methods have been proposed to estimate the glomerular filtration rate (GFR) from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare alternative methods, we calculated the GFR in several different ways from measurements in 33 patients and compared the results with an independent GFR measurement based on eight-point plasma clearance of ytterbium Yb 169-DTPA. The best agreement was obtained using an algorithm that has not been described previously, in which correction was made for overlap of the kidneys by the liver and spleen. The correlation coefficient was 0.958, and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with a correlation coefficient of 0.837 and a residual standard deviation of 23.1 ml/min. The accuracy of these methods was comparable to that reported for creatinine clearance, the most commonly used estimate of the GFR in current clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.