The blood-brain barrier (BBB) is a unique feature of the human body, preserving brain homeostasis and preventing toxic substances to enter the brain. However, in various neurodegenerative diseases, the function of the BBB is disturbed. Mechanisms of the breakdown of the BBB are incompletely understood and therefore a realistic model of the BBB is essential. We present here the smallest model of the BBB yet, using a microfluidic chip, and the immortalized human brain endothelial cell line hCMEC/D3. Barrier function is modulated both mechanically, by exposure to fluid shear stress, and biochemically, by stimulation with tumor necrosis factor alpha (TNF-α), in one single device. The device has integrated electrodes to analyze barrier tightness by measuring the transendothelial electrical resistance (TEER). We demonstrate that hCMEC/D3 cells could be cultured in the microfluidic device up to 7 days, and that these cultures showed comparable TEER values with the well-established Transwell assay, with an average (± SEM) of 36.9 Ω.cm(2) (± 0.9 Ω.cm(2)) and 28.2 Ω.cm(2) (± 1.3 Ω.cm(2)) respectively. Moreover, hCMEC/D3 cells on chip expressed the tight junction protein Zonula Occludens-1 (ZO-1) at day 4. Furthermore, shear stress positively influenced barrier tightness and increased TEER values with a factor 3, up to 120 Ω.cm(2). Subsequent addition of TNF-α decreased the TEER with a factor of 10, down to 12 Ω.cm(2). This realistic microfluidic platform of the BBB is very well suited to study barrier function in detail and evaluate drug passage to finally gain more insight into the treatment of neurodegenerative diseases.
Proximal tubules in the kidney play a crucial role in reabsorbing and eliminating substrates from the body into the urine, leading to high local concentrations of xenobiotics. This makes the proximal tubule a major target for drug toxicity that needs to be evaluated during the drug development process. Here, we describe an advanced in vitro model consisting of fully polarized renal proximal tubular epithelial cells cultured in a microfluidic system. Up to 40 leak-tight tubules were cultured on this platform that provides access to the basolateral as well as the apical side of the epithelial cells. Exposure to the nephrotoxicant cisplatin caused a dose-dependent disruption of the epithelial barrier, a decrease in viability, an increase in effluent LDH activity, and changes in expression of tight-junction marker zona-occludence 1, actin, and DNA-damage marker H2A.X, as detected by immunostaining. Activity and inhibition of the efflux pumps P-glycoprotein (P-gp) and multidrug resistance protein (MRP) were demonstrated using fluorescence-based transporter assays. In addition, the transepithelial transport function from the basolateral to the apical side of the proximal tubule was studied. The apparent permeability of the fluorescent P-gp substrate rhodamine 123 was decreased by 35% by co-incubation with cyclosporin A. Furthermore, the activity of the glucose transporter SGLT2 was demonstrated using the fluorescent glucose analog 6-NBDG which was sensitive to inhibition by phlorizin. Our results demonstrate that we developed a functional 3D perfused proximal tubule model with advanced renal epithelial characteristics that can be used for drug screening studies.
Selection of healthy spermatozoa is of crucial importance for the success rates of assisted reproduction technologies (ART) such as in vitro fertilization and intra-cytoplasmic sperm injection. Although sperm selection for ART procedures is predominantly based on sperm motility, successful fertilization is not predicted by good motility alone. For example, sperm characteristics such as the acrosome state and DNA integrity have shown significant impact on ART outcome. Although fertilization can be achieved with a single spermatozoon of high quality, current quality assessments are population-based and do not allow investigation of multiple sperm characteristics on a single spermatozoon simultaneously. In order to study sperm cells on the single cell level, we designed and characterized a PDMS microfluidic platform that allows single sperm entrapment. After spatially confining individual sperm cells within microfluidic cell traps, the cell viability, chromosomal content and acrosome state were studied. This platform is suitable for the analysis of individual sperm cells, which could be exploited for (non-invasive) sperm analysis and selection by impedance or Raman spectroscopy.
The use of high quality semen for artificial insemination in the livestock industry is essential for successful outcome. Insemination using semen with a high number of sperm cells containing morphological defects has a negative impact on fertilization outcome. Therefore, semen with a high number of these abnormal cells is discarded in order to maintain high fertilization potential, resulting in the loss of a large number of morphologically normal sperm cells (up to 70-80% of original sample). A commonly occurring morphological sperm anomaly is the cytoplasmic droplet on the sperm flagella. Currently, no techniques are available to extract morphologically normal sperm cells from rejected samples. Therefore, we aim to develop a microfluidic setup which is able to detect and sort morphologically normal sperm cells label-free and non-invasively. In a proof-of-concept experiment, differential impedance measurements were used to detect the presence of cytoplasmic droplets on sperm flagella, which was quantified by calculating the area under the curve (AUC) of the corresponding impedance peaks. A receiver operating characteristic curve of this electrical analysis method showed the good predictive power of this analysis method (AUC value of 0.85). Furthermore, we developed a label-free cell sorting system using LabVIEW, which is capable of sorting sperm cells based on impedance. In a proof-of-concept experiment, sperm cells and 3 μm beads were sorted label-free and non-invasively using impedance detection and dielectrophoresis sorting. These experiments present our first attempt to perform sperm refinement using microfluidic technology.
In this article, we describe the development of a high throughput platform to spatially manipulate viable sperm for motility measurements and recovery of the best single sperm for fertilization purposes. Micro-contact printing was used to pattern islands of adhesive proteins (fibronectin) separated by sperm repellent species (Pluronic acid F-127) on commercially available polystyrene substrates. Following washing, arrays of viable single sperm were captured onto the islands demonstrating for the first time that sperm can be trapped by micro-contact printing with patterning efficiency of 90% while retaining 100% viability. These were then subjected to motility analysis whilst remaining spatially confined to the islands. Single sperm motility was assessed (n = 37) by software analysis measuring the number of rotations per second (degrees s⁻¹). The assignment of array coordinates allows the more active single sperm to be easily identified and recovered by a simple micromanipulator pipette aspiration step with automated possibility for assisted reproductive technologies or further quality correlation analysis. Taken together, we show for the first time a technique to simultaneously screen thousands of viable single sperm for motility assessment while retaining the ability for single species recovery for enhanced fertilization purposes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.