Compressed air energy storage (CAES) in porous formations is considered as one option for large-scale energy storage to compensate for fluctuations from renewable energy production. To analyse the feasibility of such a CAES application and the deliverability of an underground porous formation, a hypothetical CAES scenario using an anticline structure is investigated. Two daily extraction cycles of 6 h each are assumed, complementing high solar energy production around noon. A gas turbine producing 321 MW of power with a minimum inlet pressure of 43 bar at 417 kg s
−1
air is assumed. Simulation results show that using six wells the 20 m-thick storage formation with a permeability of 1000 mD can support the required 6 h continuous power output of 321 MW, even reaching 8 h maximally. For the first 30 min, maximum power output is higher, at 458 MW, continuously dropping afterwards. A sensitivity analysis shows that the number of wells required does not linearly decrease with increasing permeability of the storage formation due to well inference during air extraction. For each additional well, the continuous power output increases by 4.8 h and the maximum power output within the first 30 min by 76 MW.
In order to compensate for the variable mismatch between heat demand and heat production from renewable sources or waste heat, high-temperature aquifer thermal energy storage (HT-ATES) is a promising option. A reliable prediction of the energetic performance as well as thermal and hydraulic impacts of a HT-ATES requires a suitable model parameterization regarding the subsurface properties. In order to identify the subsurface parameters on which investigation efforts should be focused, we carried out an extensive sensitivity analysis of the thermal and hydraulic parameters for a high-temperature heat injection test (HIT) using numerical modeling of the governing coupled thermo-hydraulic processes. The heat injection test was carried out in a quaternary shallow aquifer using injection temperatures of about 75 °C over 5 days, accompanied by an extensive temperature monitoring. The sensitivity analysis is conducted for parameter ranges based on literature values, based on site investigation at the HIT site and based on a model calibrated to the measured temperature distribution following the heat injection. Comparing the parameter ranges thus obtained in this three-step approach allows to identify those parameters, for which model prediction uncertainty decreased most, which are also the parameters, that strongly affect the thermal behavior. The highest sensitivity is found for vertical and horizontal hydraulic conductivity as well as for groundwater flow velocity, indicating that investigation efforts for HT-ATES projects should focus on these parameters. Heat capacity and thermal conductivity have a smaller impact on the temperature distribution. Our work thus yields a consistent approach to identifying the parameters which can be best restricted by field investigations and subsequent model calibration. Focusing on these during field investigations thus enable improved model predictions of both HT-ATES operation and induced impacts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.