BackgroundIndependent external audits play an important role in quality assurance programme in radiation oncology. The audit supported by the IAEA in Serbia was designed to review the whole chain of activities in 3D conformal radiotherapy (3D-CRT) workflow, from patient data acquisition to treatment planning and dose delivery. The audit was based on the IAEA recommendations and focused on dosimetry part of the treatment planning and delivery processes.MethodsThe audit was conducted in three radiotherapy departments of Serbia. An anthropomorphic phantom was scanned with a computed tomography unit (CT) and treatment plans for eight different test cases involving various beam configurations suggested by the IAEA were prepared on local treatment planning systems (TPSs). The phantom was irradiated following the treatment plans for these test cases and doses in specific points were measured with an ionization chamber. The differences between the measured and calculated doses were reported.ResultsThe measurements were conducted for different photon beam energies and TPS calculation algorithms. The deviation between the measured and calculated values for all test cases made with advanced algorithms were within the agreement criteria, while the larger deviations were observed for simpler algorithms. The number of measurements with results outside the agreement criteria increased with the increase of the beam energy and decreased with TPS calculation algorithm sophistication. Also, a few errors in the basic dosimetry data in TPS were detected and corrected.ConclusionsThe audit helped the users to better understand the operational features and limitations of their TPSs and resulted in increased confidence in dose calculation accuracy using TPSs. The audit results indicated the shortcomings of simpler algorithms for the test cases performed and, therefore the transition to more advanced algorithms is highly desirable.
Background and purpose. one of the newer audit modalities operated by the international atomic Energy agency (iaEa) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried out in eight European countries-Estonia,
This study shows that registration and image fusion allows precise target localization in terms of GTV and CTV and local disease control.
Background: The IAEA recommends a quality assurance program in radiotherapy to ensure safe and effective treatments. In this study, radiotherapy departments were surveyed on their current practice including the extent and depth of quality assurance activities. Methods: Radiotherapy departments were voluntarily surveyed in three stages, firstly, in basic facility information, secondly, in quality assurance activities and treatment techniques, and thirdly, in a snapshot of quality assurance, departmental and treatment activities. Results: The IAEA received completed surveys from 381 radiotherapy departments throughout the world with 100 radiotherapy departments completing all three surveys. Dominant patterns were found in linac-based radiotherapy with access to treatment planning systems for 3D-CRT and 3D imaging. Staffing levels for major staff groups were on average in the range recommended by the IAEA. The modal patient workload per EBRT unit was as expected in the range of 21-30 patients per day, however significant instances of high workload (more than 50 patients per day per treatment unit) were reported. Staffing levels were found to correlate with amount of treatment equipment and patient workload. In a self-assessment of quality assurance performance, most radiotherapy departments reported that they would perform at least 60% of the quality assurance activities itemized in the second survey, with particular strength in equipment quality control. In a snapshot survey of quality assurance performance, again equipment quality control practice was well developed, particularly for the treatment equipment. Conclusions: The IAEA surveys provide a snapshot of current radiotherapy practice including quality assurance activities.
Introduction.Enhanced dynamic wedges (EDW) are known to increase drastically the radiation therapy treatment efficiency. This paper has the aim to compare linear array measurements of EDW with the calculations of treatment planning system (TPS) and the electronic portal imaging device (EPID) for 15 MV photon energy.Materials and methods.The range of different field sizes and wedge angles (for 15 MV photon beam) were measured by the linear chamber array CA 24 in Blue water phantom. The measurement conditions were applied to the calculations of the commercial treatment planning system XIO CMS v.4.2.0 using convolution algorithm. EPID measurements were done on EPID-focus distance of 100 cm, and beam parameters being the same as for CA24 measurements.ResultsBoth depth doses and profiles were measured. EDW linear array measurements of profiles to XIO CMS TPS calculation differ around 0.5%. Profiles in non-wedged direction and open field profiles practically do not differ. Percentage depth doses (PDDs) for all EDW measurements show the difference of not more than 0.2%, while the open field PDD is almost the same as EDW PDD. Wedge factors for 60 deg wedge angle were also examined, and the difference is up to 4%. EPID to linear array differs up to 5%.ConclusionsThe implementation of EDW in radiation therapy treatments provides clinicians with an effective tool for the conformal radiotherapy treatment planning. If modelling of EDW beam in TPS is done correctly, a very good agreement between measurements and calculation is obtained, but EPID cannot be used for reference measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.