The relaxed atomic geometries of the low-index cleavage surfaces of wurtzite-structure CdSe are determined via comparison of dynamical scattering calculations with measured low-energyelectron-difFraction (LEED) and low-energy-positron-difFraction (LEPD) intensities. Both surfaces are found to be relaxed in accordance with recently proposed geometries deduced from total-energyminimization calculations. Since this analysis represents the use of LEPD for quantitative surfacestructure determination, we discuss the experimental technique, the differences observed between LEPD and LEED, and the complementary nature of the two spectroscopies.
A 1500-A Ni(100) film is back illuminated with 5-keV positrons from a brightness-enhanced slow positron beam. Some of the positrons diffuse through the film and are emitted from the front surface by virtue of the Ni having a negative positron affinity. An immersion objective and projector lens form a 1150x image of the reemitted positrons at a 2D position-sensitive detector. With a resolution of 3000 ± 1000 A we observe patches attributable to positron trapping at boundary layers inside the film. The advantages and ultimate capabilities of the positron reemission microscope are also discussed.
Low-energy positron diffraction (LEPD) is used in conjunction with low-energy electron diffraction (LEED) to determine the relaxed atomic geometries of the CdSe cleavage surfaces. The LEPD analyses yield optimal fits at smaller top-layer perpendicular relaxations than LEED for both cleavage faces, and significantly better agreement between theoretical and experimental intensity profiles.During the past decade, low-energy electron diffraction (LEED) has become a powerful tool for the structural determination of ordered surfaces. ! " 3 In spite of the success of LEED in determining the surface structure of compound semiconductors, the agreement between observed diffracted-beam profiles I ex (V) and calculated profiles Ith(V) has not been as good as for metal and adsorbate-on-metal surfaces. Although the reason for this is not yet fully understood, the higher degree of complexity due to relaxations extending below the outermost one or two atomic layers is commonly regarded as a major factor. Because of the large differences between diffracted-beam intensity profiles observed via LEED and low-energy positron diffraction (LEPD), 4 " 6 comparison of LEED and LEPD structural determinations of a compound semiconductor surface would provide additional insight into this issue and could yield a more accurate structural determination than one using LEED alone. Accordingly, we have carried out LEPD and LEED structural determinations of the relaxed atomic geometries of the recently determined 7 (lOTO) and previously undetermined (1120) cleavage faces of CdSe. We find that both the LEPD and LEED results are consistent with the relaxation predicted by Wang and Duke. 8 In addition, the agreement between I ex (V) and Ith (V) for LEPD is, surprisingly, observed to be significantly better than for LEED. For both cleavage faces, we also find smaller top-layer perpendicular relaxations for the LEPD structure analyses than for the LEED analyses, although the differences may be viewed as lying barely within the uncertainty of the analyses. We have established that the LEPD-LEED differences are not experimental artifacts by obtaining both LEPD and LEED data from the same sample surfaces in the same apparatus at Brandeis University. The validity of the Brandeis LEED results was then checked by comparison with LEED data and structural analyses carried out at Princeton University.The LEPD intensities were obtained with the brightness-enhanced, slow positron beam at Brandeis. 9 A 230-mCi 58 Co positron source produced a final positron beam of 5000 s _1 , monochromatic within 0.2 eV and having a phase space of 1 mmdeg over the energy range 20-200 eV. The beam optics also produced a 1-mm-deg electron beam, allowing the collection of LEED intensities from the same sample surfaces as the LEPD. The normal-incidence diffractometer incorporated a channel electron multiplier array and resistive anode encoder. Details of the diffractometer and beam design are given elsewhere. 1011 The CdSe(lOlO) and CdSe(1120) samples were high-purity, Cd-rich, lo...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.