Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: (i) rapid and efficient mixing between streams, (ii) multiple laminar flows with minimal mixing between streams, and (iii) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serumcontaining media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for highthroughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use.pump ͉ valve ͉ bioreactor ͉ mixer ͉ perfusion A dvanced microfluidic cellular assays (1-6) and microscale tissue engineering studies (7-10) would benefit from robust and convenient methods to computer-control accurate spatiotemporal patterns of microfluidic flows in arrays of fluidic networks. In the past, fluidic control included syringe pumps (11), hydrogel valves (12), gravity-driven pumps (13), evaporation-based pumps (14, 15), acoustic pumps (16), gas-generationbased pumps (17, 18), and centrifugal force in CD chips (19). Electrokinetic flow (20-22), thermopneumatic (23, 24), pneumatic͞hydraulic (25), or mechanical (26, 27) valves and pumps have a high degree of control, but require external connection lines to larger equipment for actuation. A few fully integrated and self-packaged systems (23, 28) have been developed, but lack the reconfigurability inherent with numerous active valves and pumps.Here, we report a method to precisely control fluid flow inside elastomeric capillary networks by using multiple (tens to hundreds) computer-controlled, piezoelectric, movable pins. These pins are positioned as a grid on a refreshable Braille display (e.g., F. H. Papenmeier, Schwerte, Germany), which is a tactile device used by the visually impaired to read computer text. Each pin can act as a valve and be shifted upward to push against channels contained in silicone rubber and completely shut the channel. Three sequential valves of this...
This paper describes a self-contained integrated microfluidic system that can separate motile sperm from small samples that are difficult to handle using conventional sperm-sorting techniques. The device isolates motile sperm from nonmotile sperm and other cellular debris, based on the ability of motile sperm to cross streamlines in a laminar fluid stream. The device is small, simple, and disposable yet is an integrated system complete with sample inlets, outlets, sorting channel, and a novel passively driven pumping system that provides a steady flow of liquid; it requires no external power source or controls. The device fulfills a need in clinical settings where small amounts of sperm need to be sorted. It also opens the way for convenient bioassays based on sperm motility including at-home motile sperm tests.
Background The objective was to examine effects of gonadal hormone manipulation on aortic diameter and macrophage infiltration in rodents during abdominal aortic aneurysm (AAA) formation. Methods Experiment 1: 17-β estradiol and testosterone pellets were implanted in male (ME) and female (FT) rats. No pellet was implanted in shams (MES, FTS). Experiment 2: Testes and ovaries were removed from males (MO) and females (FO), respectively. No organs were removed from shams (MOS, FOS). Experiment 3: Male and female rats were orchiectomized and oophorectomized, respectively. Four weeks post-castration, testosterone (MOT) and 17-β estradiol (FOE) pellets were implanted. Shams underwent castration, but no pellet was implanted (MOTS, FOES). All rats underwent infrarenal aortic infusion with elastase postimplantation/postcastration. Diameters were measured on postoperative d 14. Tissue was stained for macrophages by immunohistochemistry. Results Diameter (P = 0.046) and macrophage counts (P = 0.014) decreased in ME compared with shams, but not in females treated with testosterone (FT). Diameter (P = 0.019) and macrophage infiltration (P = 0.024) decreased in MO compared with shams, but not in FO. Diameter increased in MOT compared with MOTS (P = 0.033), but decreased in FOE compared with FOES (P = 0.002). Macrophages decreased in FOE compared with FOES (P = 0.002). Conclusion This study documents a decrease in AAA diameter in males treated with estrogen or undergoing orchiectomy, but no changes in females treated with testosterone or undergoing oophorectomy; and an increase in diameter in MOT and a decrease in FOE. These data suggest that gonadal hormones differentially regulate AAA growth in association with changes in macrophages.
Female gender appears to be protective in the development of abdominal aortic aneurysms (AAAs). This study sought to identify gender differences in cytokine and chemokine expression in an experimental rodent AAA model. Male and female rodent aortas were perfused with either saline (control) or elastase to induce AAA formation. Aortic diameter was determined and aortic tissue was harvested on postperfusion days 4 and 7. Cytokine and chemokine gene expression was examined using focused gene arrays. Immunohistochemistry was used to quantify aortic leukocyte infiltration. Data were analyzed by Student's t-tests and ANOVA. Elastase-perfused female rodents developed significantly smaller aneurysms compared to males by day 7 (93 +/- 10% vs. 201 +/- 25%, P = 0.003). Elastase-perfused female aortas exhibited a fivefold decrease in expression of the BMP family and ligands of the TNF superfamily compared to males. In addition, the expression of members of the TGF beta and VEGF families were three to fourfold lower in female elastase-perfused aortas compared to males. Multiple members of the interleukin, CC chemokine receptor, and CC ligand families were detectable in only the male elastase-perfused aortas. Female elastase-perfused aortas demonstrated a corollary twofold lower neutrophil count (females: 17.5 +/- 1.1 PMN/HPF; males: 41 +/- 5.2 neutrophils/HPF, P = 0.01) and a 1.5-fold lower macrophage count (females: 12 +/- 1.1 macrophages/HPF; males: 17.5 +/- 1.1 macrophages/HPF, P = 0.003) compared to male elastase-perfused aortas. This study documents decreased expression of multiple cytokines and chemokines and diminished leukocyte trafficking in female rat aortas compared to male aortas following elastase perfusion. These genes may contribute to the gender disparity seen in AAA formation.
The selective estrogen receptor modulator tamoxifen inhibits the development of AAAs in male rats in association with an up-regulation of catalase and inhibition of aortic wall neutrophil infiltration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.