Tremendous progress has been made over the past few decades to develop skin substitutes for the management of acute and chronic wounds. With the advent of tissue engineering and the ability to combine advanced manufacturing technologies with biomaterials and cell culture systems, more biomimetic tissue constructs have been emerged. Synthetic and natural biomaterials are the main constituents of these skin-like constructs, which play a significant role in tissue grafting, the body's immune response, and the healing process. The act of implanting biomaterials into the human body is subject to the body's immune response, and the complex nature of the immune system involves many different cell types and biological processes that will ultimately determine the success of a skin graft. As such, a large body of recent studies has been focused on the evaluation of the performance and risk assessment of these substitutes. This review summarizes the past and present advances in in vitro, in vivo and clinical applications of tissue-engineered skins. We discuss the role of immunomodulatory biomaterials and biomaterials risk assessment in skin tissue engineering. We will finally offer a roadmap for regulating tissue engineered skin substitutes.
Self-filling microwell arrays hold great promise for the production of 3D tumor spheroids and organoids for disease modeling and drug discovery.
Proteins present an ecofriendly alternative to many of the synthetic components currently used in electronics. They can therefore in combination with flexibility and electroactivity uncover a range of new opportunities in the field of flexible and green electronics. In this study, silk‐based ionic conductors are turned into stable thin films by embedding them with 2D nanoclay platelets. More specifically, this material is utilized to develop a flexible and ecofriendly motion‐sensitive touchscreen device. The display‐like sensor can readily transmit light, is easy to recycle and can monitor the motion of almost any part of the human body. It also displays a significantly lower sheet resistance during bending and stretching regimes than the values typically reported for conventional metallic‐based conductors, and remains fully operational after mechanical endurance testing. Moreover, it can operate at high frequencies in the kilohertz (kHz) range under both normal and bending modes. Notably, our new technology is available through a simple one‐step manufacturing technique and can therefore easily be extended to large‐scale fabrication of electronic devices.
Wound infection is a major clinical challenge that can significantly delay the healing process, can create pain, and requires prolonged hospital stays. Pre-clinical research to evaluate new drugs normally involves animals. However, ethical concerns, cost, and the challenges associated with interspecies variation remain major obstacles. Tissue engineering enables the development of in vitro human skin models for drug testing. However, existing engineered skin models are representative of healthy human skin and its normal functions. This paper presents a functional infected epidermis model that consists of a multilayer epidermis structure formed at an air-liquid interface on a hydrogel matrix and a three-dimensionally (3D) printed vascular-like network. The function of the engineered epidermis is evaluated by the expression of the terminal differentiation marker, filaggrin, and the barrier function of the epidermis model using the electrical resistance and permeability across the epidermal layer. The results showed that the multilayer structure enhances the electrical resistance by 40% and decreased the drug permeation by 16.9% in the epidermis model compared to the monolayer cell culture on gelatin. We infect the model with Escherichia coli to study the inflammatory response of keratinocytes by measuring the expression level of pro-inflammatory cytokines (interleukin 1 beta and tumor necrosis factor alpha). After 24 h of exposure to Escherichia coli, the level of IL-1β and TNF-α in control samples were 125 ± 78 and 920 ± 187 pg/mL respectively, while in infected samples, they were 1429 ± 101 and 2155.5 ± 279 pg/mL respectively. However, in ciprofloxacin-treated samples the levels of IL-1β and TNF-α without significant difference with respect to the control reached to 246 ± 87 and 1141.5 ± 97 pg/mL respectively. The robust fabrication procedure and functionality of this model suggest that the model has great potential for modeling wound infections and drug testing.
Three-dimensional (3D) bioprinting of photo-cross-linkable hydrogel precursors has attracted great interest in various tissue engineering and drug screening applications, as the biochemical and biophysical properties of the resultant hydrogel structures can be tuned spatiotemporally to provide cells with physiologically relevant microenvironments. In particular, these bioinks benefit from great biofunctional versatility that can be designed to direct cells toward a desired behavior. Despite significant progress in the field, the 3D printing of cell-laden photo-cross-linkable bioinks with low polymer concentrations has remained a challenge, as rapidly stabilizing these bioinks and transforming them to hydrogel filaments is hindered by their low viscosity. Additionally, reaching an optimized print condition has often been challenging due to the large number of print parameters involved in 3D bioprinting setups. Therefore, computational modeling has occasionally been employed to understand the impact of various print parameters and reduce the time and resources required to determine these effects in experimental settings. Here, we report a novel 3D bioprinting strategy for fabricating hydrogel fibrous structures of gelatin methacryloyl (GelMA) with superior control over polymer concentration, particularly in a relatively low range from ∼1% (w/v) to 6% (w/v), using a microfluidic printhead. The printhead features a coaxial core–sheath flow, coupled with a photo-cross-linking system, allowing for the in situ cross-linking of GelMA and the generation of hydrogel filaments. A computational model was developed to determine the optimal ranges of process parameters and inform about the diffusive and fluid dynamic behavior of the coaxial flow. The cytocompatibility of the biofabrication system was determined via bioprinting cell-laden bioinks containing U87-MG cells. Notably, the established pipeline from computational modeling to bioprinting has great potential to be applied to a wide range of photo-cross-linkable bioinks to generate living tissues with various material and cellular characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.