Background Pacifiers have been shown to affect maxillary growth related to the anatomic structure of the palate and forces placed upon it during sucking. This study compares and evaluates the mechanical behavior of pacifiers of different design and size (i.e., fit), identified by brand and size, positioned in age-specific palatal models with respect to both contact area and force when subjected to peristaltic tongue function and intraoral pressure related to non-nutritive sucking. Methods Nonlinear finite element analyses were used to simulate dynamic mechanical interaction between the pacifiers and palates. Time-varying, external pressure loads were applied which represent intraoral pressure arising from non-nutritive sucking and peristaltic behavior of the tongue. The silicone rubber pacifier bulb was represented using a hyperelastic material model. Results Results from the finite element analyses include deformation, stress, strain, contact area, and contact force. Mechanical interaction was evaluated in terms of the spatial distribution of the contact area and force between the pacifier and the palate. The resulting palatal interaction profiles were quantitatively compared to assess how pacifier fit specifically affects the support provided to two areas of the palate, the palatal vault and the Tektal wall. Conclusions Pacifiers interact with the palate differently based on their fit (i.e., design and size) regardless of whether they are labeled conventional or orthodontic. Finite element analysis is an effective tool for evaluating how a pacifier’s design affects functional mechanics and for providing guidance on biometric sizing.
Hemorrhage and bacterial infections are major hurdles in the management of life‐threatening surgical wounds. Most bioadhesives for wound closure lack sufficient hemostatic and antibacterial properties. Furthermore, they suffer from weak sealing efficacy, particularly for stretchable organs, such as the lung and bladder. Accordingly, there is an unmet need for mechanically robust hemostatic sealants with simultaneous antibacterial effects. Here, an injectable, photocrosslinkable, and stretchable hydrogel sealant based on gelatin methacryloyl (GelMA), supplemented with antibacterial zinc ferrite (ZF) nanoparticles and hemostatic silicate nanoplatelets (SNs) for rapid blood coagulation is nanoengineered. The hydrogel reduces the in vitro viability of Staphylococcus aureus by more than 90%. The addition of SNs (2% w/v) and ZF nanoparticles (1.5 mg mL−1) to GelMA (20% w/v) improves the burst pressure of perforated ex vivo porcine lungs by more than 40%. Such enhancement translated to ≈250% improvement in the tissue sealing capability compared with a commercial hemostatic sealant, Evicel. Furthermore, the hydrogels reduce bleeding by ≈50% in rat bleeding models. The nanoengineered hydrogel may open new translational opportunities for the effective sealing of complex wounds that require mechanical flexibility, infection management, and hemostasis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.