Glycosaminoglycans (GAGs) are important structural and functional components in native aortic heart valves and in glutaraldehyde (Glut)-fixed bioprosthetic heart valves (BHVs). However, very little is known about the fate of GAGs within the extracellular matrix of BHVs and their contribution to BHV longevity. BHVs used in heart valve replacement surgery have limited durability due to mechanical failure and pathologic calcification. In the present study we bring evidence for the dramatic loss of GAGs from within the BHV cusp structure during storage in saline and both shortand long-term Glut fixation. In order to gain insight into role of GAGs, we compared properties of fresh and Glut-fixed porcine heart valve cusps before and after complete GAG removal. GAG removal resulted in significant morphological and functional tissue alterations, including decreases in cuspal thickness, reduction of water content and diminution of rehydration capacity. By virtue of this diminished hydration, loss of GAGs also greatly increased the ''with-curvature'' flexural rigidity of cuspal tissue. However, removal of GAGs did not alter calcification potential of BHV cups when implanted in the rat subdermal model. Controlling the extent of pre-implantation GAG degradation in BHVs and development of improved GAG crosslinking techniques are expected to improve the mechanical durability of future cardiovascular bioprostheses.
We have developed a novel highly articulated robotic probe (HARP) that can thread through tightly packed volumes without disturbing the surrounding tissues and organs. We use cardiac surgery as the focal application of this work. As such, we have designed the HARP to enter the pericardial cavity through a subxiphoid port. The surgeon can effectively reach remote intrapericardial locations on the epicardium and deliver therapeutic interventions under direct control. Our device differs from others in that we use conventional actuation and still have great maneuverability. We have performed proof-of-concept clinical experiments to give us preliminary validation of the ideas presented here.
Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.
Polyurethane (PU) components of cardiovascular devices are subjected to oxidation-initiated surface degradation, which leads to cracking and ultimately device failure. In the present study, we investigated a novel bromoalkylation chemical strategy to covalently attach the antioxidant, di-tert-butylphenol (DBP), and/or cholesterol (Chol) to the PU urethane nitrogen groups to hypothetically prevent oxidative degradation. These experiments compared PU, PU-DBP, PU-Chol, and PU-Chol-DBP. A series of comparative oxidative degradation studies involved exposing PU samples (modified and unmodified) to H2O2-CoCl2 for 15 days at 37 degrees C, to cause accelerated oxidative degradation. The extent and effects of degradation were assessed by attenuated total reflectance Fourier transformation infrared spectroscopy (FTIR), scanning electron microscopy (SEM), surface contact angle measurements, and mechanical testing. Both the Chol and DBP modification conferred significant resistance to oxidation related changes compared to unmodified PU per FTIR and SEM results. SEM demonstrated cavitation only in unmodified PU. However, contact angle analysis showed significant oxidation-induced changes only in the Chol-modified PU formulations. Most importantly, uniaxial stress-strain testing revealed that only PU-DBP demonstrated bulk elastomeric properties that were minimally affected by oxidation; PU, PU-Chol, PU-Chol-DBP showed marked deterioration of their stress-strain properties following oxidation. In conclusion, these results demonstrate that derivatizing PU with DBP confers significant resistance to oxidative degradation compared with unmodified PU.
While bioprosthetic heart valves (BHV) remain the primary treatment modality for adult heart valve replacement, continued problems with durability remain. Several studies have implicated flexure as a major damage mode in porcine-derived heterograft biomaterials used in BHV fabrication. While conventional accelerated wear testing can provide valuable insights into BHV damage phenomena, the constituent tissues are subjected to complex, time-varying deformation modes (i.e. tension and flexure), that do not allow for the control of the amount, direction, and location of flexure. Thus, in the present study customized fatigue testing devices were developed to subject circumferentially oriented porcine BHV tissue strips to controlled cyclic flexural loading. By using this approach, we were able to study layer-specific structural damage induced by cyclic flexural tensile and compressive stresses alone. 10×106, 25×106 and 50×106 cycle levels were used, with resulting changes in flexural stiffness and collagen structure assessed. Results indicated that flexural rigidity was markedly reduced after only 10×106 cycles, and progressively decayed at a lower rate with cycle number thereafter. Moreover, the against-curvature fatigue direction induced the most damage, suggesting that the ventricularis and fibrosa layers have low resistance to cyclic flexural compressive and tensile loads, respectively. The histological analyses indicated progressive collagen fiber delamination as early as 10×106 cycles, but otherwise no change in gross collagen orientation. Our results underscore that porcine-derived heterograft biomaterials are very sensitive to flexural fatigue, with delamination of the tissue layers the primary underlying mechanism. This appears to be in contrast to pericardial BHV, wherein high tensile stresses are considered to be the major cause of structural failure. These findings point towards the need for the development of chemical fixation technologies that minimize flexure induced damage to extend porcine heterograft biomaterial durability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.