There has, in recent years, been a major revival of interest in glass-and glass-ceramic-to-metal seals and coatings for new applications. Experience dictates that many factors need to be taken into consideration in the successful design and manufacture of high-quality seals, particularly if an adequate component lifetime is to be achieved. For example, during their preparation, undesirable reactions may occur between diffusing metal species and glass constituents, and these can lead to the formation of highly localized internal stresses, which can initiate failure of a seal either during manufacture or, more seriously, whilst in service due to the influence of static fatigue. In the case of high-temperature systems, reactions under hostile operating conditions also need to be taken into consideration. In this review, the factors learnt from past experience that influence the formation and lifetime behaviour of glass and glass-ceramic/metal systems are briefly introduced, and their relevance to the newer applications including solid oxide fuel cell sealants and coatings on titanium for biomedical applications is discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.