task and psychosocial risk factors for work-related musculoskeletal disorders among newspaper employees. Scand J Work Environ Health 1994;20:417-26.OBJECTIVES -A cross-sectional study was conducted to assess the association of upper extremity musculoskeletal disorders and work-related factors among employees using video display terminals at a large metropolitan newspaper.METHODS -The study included 1050 randomly selected workers from four departments. The workers were asked to complete questionnaires on symptoms, job tasks, and psychosocial and work organization conditions. Musculoskeletal disorders of the upper extremities were defined by frequency, duration, and intensity of symptoms not attributable to acute injury. Data were analyzed with the use of logistic regression. RESULTS -A total of 973 workers completed the survey. The one-year period prevalence rate for any musculoskeletal disorder of the upper extremities was 41%. Neck symptoms (26%) were the most frequently reported, followed by hand or wrist (22%), shoulder (17%), and elbow (10%) symptoms. Greater time working at the video display station was associated with increased hand or wrist symptoms in a dose-response relationship. In addition, variables corresponding to increased work-load demands (eg, increased time working under deadline and increased job pressure) were associated with increased neck, shoulder, and hand or wrist disorders. Women were more likely to report symptoms in several areas, but this finding may reflect the concentration of women in jobs involving more risk factors. CONCLUSIONS -The results suggest a high prevalence of musculoskeletal disorders of the upper extremities among newspaper employees, and they provide additional evidence that increased work load, time pressure, and greater hours of computer use are related to the occurrence of work-related musculoskeletal disorders among these workers, particularly for disorders in the hand or wrist area.
The relationship between workplace factors and work-related upper extremity musculoskeletal disorders (UE disorders) was assessed in a cross-sectional study of 533 telecommunication employees utilizing video display terminals (VDTs). Cases of UE disorders were defined using symptom questionnaires and physical examinations. Data on demographics, individual factors (medical conditions and recreational activities), work organization and practices, and psychosocial aspects of work, including electronic performance monitoring (EPM), were obtained by questionnaire. Associations between workplace factors and UE disorders were assessed by multiple logistic models generated for each of the four UE areas (neck, shoulder, elbow, hand/wrists). One-hundred and eleven (22%) participants met our case definition for UE disorders. Probable tendon-related disorders were the most common (15% of participants). Probable nerve entrapment syndromes were found in 4% of participants. The hand/wrist was the area most affected, 12% of participants. The following variables had associations in the final models (p < 0.05) with at least one of the four UE disorders, although the strength of these associations were modest. Non-white race, a diagnosis of a thyroid condition (self-reported) use of bifocals at work, and seven psychosocial variables (fear of being replaced by computers, increasing work pressure, surges in workload, routine work lacking decision-making opportunities, high information processing demands, jobs which required a variety of tasks and lack of a production standard) were associated with UE disorders. This study indicates that work-related UE musculoskeletal disorders are relatively common among telecommunication workers who use VDTs, and adds to the evidence that the psychosocial work environment is related to the occurrence of these disorders.
BackgroundMore than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed.Methods and FindingsHere we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity.ConclusionAdvances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.
In the last decade, saliva has been advocated as a non-invasive alternative to blood as a diagnostic fluid. However, use of saliva has been hindered by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many constituents compared to serum. Furthermore, developments in the areas related to lab-on-a-chip systems for saliva-based point of care diagnostics are complicated by the high viscosity and heterogeneous properties associated with this diagnostic fluid. The biomarker C-reactive protein (CRP) is an acute phase reactant and a well-accepted indicator of inflammation. Numerous clinical studies have established elevated serum CRP as a strong, independent risk factor for the development of cardiovascular disease (CVD). CVD has also been associated with oral infections (i.e. periodontal diseases) and there is evidence that systemic CRP may be a link between the two. Clinical measurements of CRP in serum are currently performed with "high sensitivity" CRP (hsCRP) enzyme-linked immunosorbent assay (ELISA) tests that lack the sensitivity for the detection of this important biomarker in saliva. Because measurement of salivary CRP may represent a novel approach for diagnosing and monitoring chronic inflammatory disease, including CVD and periodontal diseases, the objective of this study was to apply an ultra-sensitive microchip assay system for the measurement of CRP in human saliva. Here, we describe this novel lab-on-a-chip system in its first application for the measurement of CRP in saliva and demonstrate its advantages over the traditional ELISA method. The increased sensitivity of the microchip system (10 pg ml(-1) of CRP with 1000-fold dilution of saliva sample) is attributed to its inherent increased signal to noise ratio, resulting from the higher bead surface area available for antigen/antibody interactions and the high stringency washes associated with this approach. Finally, the microchip assay system was utilized in this study to provide direct experimental evidence that chronic periodontal disease may be associated with higher levels of salivary CRP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.