The development of aortic insufficiency (AI) is known to be associated with prolonged left ventricular assist device (LVAD) support, but its overall significance with regards to long-term outcomes is unclear. This uncertainty translates to a lack of consensus regarding the management of AI in this patient population—an increasingly pertinent question as more patients are placed on LVAD support as destination therapy. A retrospective review of a single, high-volume institution was performed to assess outcomes in patients who received a HeartMate II or HeartWare (LVAD) between 2008 and 2018. Patients were stratified by AI severity at 6 months, and those with LVAD support of less than 6 months were excluded. The primary endpoint was 2 year mortality, and secondary endpoints were right heart failure and functional exercise capacity. At 6 month follow-up 111, 92, and 18 patients had no (0), mild (1), and moderate (2) AI, respectively. Moderate AI was a significant predictor of 2 year mortality in a multivariable model (p = 0.024). Functional exercise capacity (measured by 6 minute walk test) and incidence of right heart failure at 1 year were not significantly different between groups (P = 0.1421; P = 0.2189). In conclusion, moderate AI at 6 months post-LVAD implant is associated with worse long-term mortality. More aggressive management strategies targeting AI development in long-term LVAD patients may be warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.