Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms.Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2).Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform.Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults.
Frailty contributes greatly to cost of care, but while often correlated, is not synonymous with MCCs. Thus, it is important to control separately for frailty in studies that compare medical care use and cost.
Estimates of muscle tissue composition may have greater prognostic value than lean body mass levels regarding health-related outcomes. Ultrasound provides a relatively low cost, safe, and accessible mode of imaging to assess muscle morphology. The purpose of this study was to determine the construct validity of muscle echogenicity as a surrogate measure of muscle quality in a sample of older, predominantly African American (AA) participants. We examined the association of rectus femoris echogenicity with mid-thigh computed tomography (CT) scan estimates of intra- and intermuscular adipose tissue (IMAT), basic metabolic parameters via blood sample analysis, muscle strength, and mobility status. This observational study was conducted at a federal medical center and included 30 community-dwelling men (age, 62.5 ± 9.2; AA, n = 24; Caucasian, n = 6). IMAT estimates were significantly associated with echogenicity (r = 0.73, p < 0.001). Echogenicity and IMAT exhibited similar associations with the two-hour postprandial glucose values and high-density lipoproteins values (p < 0.04), as well as grip and isokinetic (180°/s) knee extension strength adjusted for body size (p < 0.03). The significant relationship between ultrasound and CT muscle composition estimates, and their comparative association with key health-related outcomes, suggests that echogenicity should be further considered as a surrogate measure of muscle quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.