The percutaneous transluminal coronary angioplasty (PTCA) is one of the interventional procedures which impart high radiation doses to patients compared to the other cardiologic procedures. This study intends to audit and optimize radiation dose imparted to patients undergoing PTCA. Forty-four patients who underwent PTCA involving single or multiple stent placement guided under cardiovascular X-ray machine were included in the study. Radiation doses were measured using dose area product (DAP) meter for patients undergoing single and multiple stent placements during PTCA. A dose reduction of 27-47% was achieved using copper filters and optimal exposure parameters. The mean DAP values before optimization were 66.16 and 122.68 Gy cm2 for single and multiple stent placement respectively. These values were 48.67 and 65.44 Gy cm2 respectively after optimization. In the present scenario, due to the increase in the number of PTCAs performed and the associated risk from radiation, periodical audit of radiation doses for interventional procedures are recommended.
Purpose:This study focuses on incorporation of a solitary dynamic portal (SDP) in conformal planning for postmastectomy radiotherapy (PMRT) with nodal regions with an intention to overcome the treatment planning limitations imposed by conventional techniques.Materials and Methods:Twenty-four patients who underwent surgical mastectomy followed by PMRT were included in this study. Initially, a treatment plan comprising tangential beams fitted to beam's-eye-view (BEV) of chest wall (CW) and a direct anterior field fitted to BEV of nodal region, both sharing a single isocenter was generated using Eclipse treatment planning system. Multiple field-in-fields with optimum beam weights (5% per field) were added primarily from the medial tangent, fitted to BEV of entire target volume, and finally converted into a dynamic portal. Dosimetric analysis for the treatment plans and fluence verification for the dynamic portals were performed.Results and Discussion:Conformal plans with SDP showed excellent dose coverage (V95%>95%), higher degree of tumor dose conformity (≤1.25) and homogeneity (≤0.12) without compromising the organ at risk sparing for PMRT with nodal region. Treatment plans with SDP considerably reduced the lower isodose spread to the ipsilateral lung, heart, and healthy tissue without affecting the dose homogeneity. Further, gamma evaluation showed more than 96% pixel pass rate for standard 3%/3 mm dose difference and distance-to-agreement criteria. Moreover, this plan offers less probability of “geometrical miss” at the highly irregular CW with regional nodal radiotherapy.Conclusion:Hybrid conformal plans with SDP would facilitate improved dose distribution and reduced uncertainty in delivery and promises to be a suitable treatment option for complex postmastectomy CW with regional nodal irradiation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.