The literature shows consensus over high rates of pedicle screw misplacement, but low clinical complications, in the hands of the best of spine surgeons. The concept of acceptable screw placements and the outcome classification makes the pedicle screw assessment results correlate better with the clinical outcome.
Our meta-analysis showed that the use of barbed sutures was associated with increased superficial infection rate and shorter estimated closure time. More RCTs are needed to examine the efficacy and safety of the barbed sutures.
We suggest that functional outcome and clinical stability may be better with anatomical double bundle anterior cruciate ligament reconstruction as compared to anatomical single bundle anterior cruciate ligament reconstruction.
Background:The key to the safe and effective use of thoracic pedicle screws in the deformed spine is to thoroughly understand pedicle anatomy. There are a few studies related to pedicle anatomy in the Indian population and no pedicle morphometric studies in scoliosis patients. The present study aims to highlight the differential features of pedicle morphometry, including pedicle width, transverse pedicle angle and the depth to anterior cortex on the concave and convex side, in a group of Indian patients with adolescent idiopathic scoliosis and compare this to that of a western population.Materials and Methods:This is a prospective study of 24 patients with adolescent idiopathic scoliosis. The average age is 14.6 years (12.3-18.3 years) of which 14 were females and 10 were males. All the patients underwent CT scan using Siemens 4th generation scanner. The scans were analyzed by measuring the transverse pedicle width, transverse pedicle angle and the chord length; all the measurements being made both on the convex as well as the concave pedicle. Statistical analysis was performed with unpaired ‘t’ test.Results:A total of 1295 measurements were performed from 24 patients and an average of 215 pedicles were assessed for each set of the measurements made. The transverse pedicle width was consistently found to be smaller on concave side in comparison with the convex side at all levels except at T1. The transverse pedicle angle was greater on the concave side at all levels as compared to the convex side, though there was wide individual variation. The depth to anterior cortex was lesser on convex side in comparison to the concave side except at T1.Conclusions:The concave pedicle is much thinner and directed more medially than the convex side, especially at the apical region of the scoliotic curve. The pedicle anatomy in scoliosis patients shows very high individual variations and a careful study of pre-operative CT scans is essential for planning proper pedicle screw placement. Slightly longer screws can be accommodated on the concave side as compared to the convex side, though the difference in the chord length is not statistically significant at most levels.
Our analysis showed a significant reduction in prevalence of CRPS with the use of vitamin C. Further high-quality RCTs with standard dosages and common diagnostic criteria are needed to be able to deliver solid conclusions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.