Wind energy converter commonly converts wind power to shaft and electric power. One of the problems of transmitting shaft power is the limited distance between the driving to the driven shaft. This paper describes an experimental study of electrical transmission from driving to the driven shaft that was carried out on three modes of cable lines transmission. The driving shaft was attached to an electric generator that converts shaft r to electric power. The driven shaft was coupled by electric motor which reconverts the electric to shaft power. The generator and motor were BLDC and BDC permanent magnet electric machines. The distance of the driving to the driven shaft was 300 meters. The electric power was transmitted using wires. The wires consisted of 2 and 3 cables commonly used by peoples and sold in market place. The results showed that electric transmission mode on the experiment has important role on performance of shaft power to electric power conversion on driving generator and energy losses on cables transmission. DC on small wires electric transmission gave total efficiency of 16.2 %. DC on large wires electric transmission gave total efficiency of 32.9 %. AC on large wires electric transmission gave total efficiency of 36.4 %.
Boron neutron cancer therapy is a cancer treatment method that encompasses epithermal neutron irradiation of boron delivered to tumor cells. Using collimators, fast neutrons are moderated into epithermal neutrons. When radiation is performed, neutron beams are emitted and filtered by a collimator. In this study, 12 collimators used in the BNCT process were inspected for their quality, in terms of defects or flaws. The inspected collimators were manufactured by centrifugal casting and were composed of 99% pure nickel. They had the following dimensions: height of 145 mm, outer diameter of 190 mm, inner diameter of 160 mm, and thickness of 15 mm. The inspection method used was gamma radiography testing with an Iridium-192 gamma source. Using a single wall single image technique, the collimators were exposed for 30 seconds. Six FUJI films were placed behind the object to record the resulting images, which showed light or dark areas on each collimator, the latter of which indicated porosity or flaws. Based on these images, collimators 1 and 5 were found to contain cracks, and porosity was identified in almost all of the collimators. It is suggested that both collimators with cracks be recycled, while the collimators with porosities should be investigated further to determine their suitability for boron neutron cancer therapy.
The purpose of this study is to determine the value of corrosion rate influenced by coastal environment and seawater to nickel as a collimator base material for the application of boron neutron capture therapy (BNCT). In this research, the authors used 99.9% pure nickel as the reference material. Corrosion testing was carried out to determine the rate of corrosion of nickel as a base material for BNCT. After the specimens were formed, the test specimens were then corroded for 12 weeks, with various conditions such as indoor, outdoor environment, static seawater, and moving seawater. The results of this study indicated that in corrosion testing with indoor condition, the corrosion rate values are 0.61-1.00 mpy. For outdoor condition, the corrosion rate is 0.89-1.34 mpy. Meanwhile, at static seawater conditions, the corrosion rate is 0.97-1.24 mpy. Lastly, for moving seawater condition, the corrosion rate is 1.64-1.91 mpy. The results showed that corrosion resistance was relatively the same for all nickel exposed to corrosion in the coastal environment. Therefore, in regards to corrosion resistance, using nickel as a collimator base material for BNCT applications is considered as safe.
The addition of Silicon (Si) on the gray cast iron can initiate graphite dispersion where the graphite becomes smaller and more evenly distributed. This study investigated the effect of Si concentration of 2.9% and 3.8% on the fatigue strength of the gray cast iron. The Si was added by the casting process with the open ladle method. The specimens were manufactured by following the ASTM E-466. Several tests such as tensile test, Brinell hardness test, and microstructure observation were conducted prior to the fatigue testing. The results showed that the Si concentration of 3.8% tended to increase the tensile strength up to 1.3%, the hardness up to 7.6%, and fatigue limit up to 10%. Moreover, the fatigue fractured specimen of 3.8% Si showed the combination of type A and type B graphite where graphite is smaller and more evenly distributed. In addition by applying the logistic equation, the fatigue strength can be predicted well.
In this study, Rockwell and Brinell hardness testing was used to examine material hardness. These methods were chosen because they are easy to carry out, relatively inexpensive, and almost all sizes and shapes can be tested, in which nickel hardness before and after centrifugal casting are identified and compared. These tests enable the determination of the hardness numbers of nickel collimators using for boron neutron capture therapy. The samples were five nickel plates with a dimension of 4.5 × 4.5 cm and five collimators. The collimators were cylindrical and made using centrifugal casting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.