We could delay surgery for an average of 9 days from VSP onset by means of IABP or respiratory management without the deterioration of organ function. The 30-day mortality and long-term outcome were favorable.
A 56-year-old man presenting with massive melena and loss of consciousness was diagnosed with an infected thoracoabdominal aneurysm, an aortoduodenal fistula, and Leriche syndrome following an evaluation by computed tomography. Emergency surgery for uncontrolled infection included the reconstruction of the superior mesenteric and bilateral renal arteries using a four-branched graft. The aortoduodenal fistula was resected after omental filling, and an enterostomy was performed for feeding. Intestinal reconstruction was performed in two stages. The patient was discharged on postoperative day 48 and was without evidence of recurrence at 23 months postoperatively.
Objectives: Patients with chronic aortic dissection often require repeat interventions due to enlargement of the pressurized false lumen or disseminated intravascular coagulation even after additional thoracic endovascular aortic repair (TEVAR) to occlude the entry tear. Residual false lumen flow can persist even after performing the candy-plug technique or branched stentgraft placement in some cases. We have devised a new method for false lumen closure. Methods: From December 2010 to May 2017, 5 patients (mean age: 57 [13] years, range: 43-77 years) with chronic dissection at the aortic arch and descending aorta, who underwent initial TEVAR, required additional treatment. Using an open surgical approach, the endograft was fixed with an outer felt under cardiopulmonary bypass after the endograft with stent was expanded by fenestration. The false lumen was closed using this procedure, and the aortotomy was repaired by direct closure in 2 cases and by graft replacement in 3 cases. Results: No major operative complications occurred, such as respiratory failure or paraplegia. Postoperative enhanced computed tomography (CT) images showed that the false lumen flow disappeared in all cases. All patients were discharged under normal conditions. They were all followed up and their CT did not indicate any complications for a mean of 33.6 (20.3) months. Conclusions: Our combined procedure was effective and provided a higher success rate compared with endovascular therapy alone. This staged treatment approach, using a combination of TEVAR and false lumen closure, is less invasive compared with open surgery alone and may represent a valid treatment option for chronic type B dissection. Keywords chronic dissection, false lumen closure, open surgery, thoracic endovascular aortic repair formation. This study reports 5 cases treated by distal neo-neck formation after TEVAR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.