Endoscopy is the gold standard for objective assessment of colonic disease activity in inflammatory bowel disease (IBD). Non-invasive colonic imaging using bowel ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) may have a role in quantifying colonic disease activity. We reviewed the diagnostic accuracy of these modalities for assessment of endoscopically or histopathologically defined colonic disease activity in IBD. We searched Embase, MEDLINE, and the Web of Science from inception to 20 September 2021. QUADAS-2 was used to evaluate the studies’ quality. A meta-analysis was performed using a bivariate model approach separately for MRI and US studies only, and summary receiver operating characteristic (ROC) curves were obtained. CT studies were excluded due to the absence of diagnostic test data. Thirty-seven studies were included. The mean sensitivity and specificity for MRI studies was 0.75 and 0.91, respectively, while for US studies it was 0.82 and 0.90, respectively. The area under the ROC curves (AUC) was 0.88 (95% CI, 0.82 to 0.93) for MRI, and 0.90 (95% CI, 0.75 to 1.00) for US. Both MRI and US show high diagnostic accuracy in the assessment of colonic disease activity in IBD patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.