The objective of this study was to investigate the effect of Er:YAG laser irradiation on shear bond strength and microleakage between resin cements and yttrium-stabilized tetragonal zirconia (Y-TZP) ceramics. Eighty disc specimens of Y-TZP ceramics (6 mm × 4 mm) were prepared. The specimens were divided into two groups according to surface treatment (control and Er:YAG laser-treated). The control and lased specimens were separated into two groups for shear bond strength test (n = 20), and microleakage evaluation (n = 10). Specimens were subjected to shear bond strength test by a universal testing machine with a crosshead speed of 1 mm/min. Specimens for microleakage evaluation were then sealed with nail varnish, stained with 0.5% basic fuchsin for 24 h, sectioned, and evaluated under a stereomicroscope. The data were analyzed with one-way ANOVA and post hoc Tukey-Kramer multiple comparisons tests (α = 0.05) for shear bond strengths and a two related-samples tests (α = 0.05) for microleakage scores. Higher bond strength values were found in the laser-treated groups compared to the control groups. Microleakage scores among the groups showed that the laser-treated specimens had lower microleakage scores than those of control specimens in the adhesive-ceramic interface. Roughening surface of Y-TZP ceramic by Er:YAG laser increased the shear bond strengths of ceramic to dentin and reduced the microleakage scores.
The purpose of this study was to investigate the tensile strength of the bond between a silicone lining material and heat-cured polymethyl methacrylate (PMMA) denture base resin after Er:YAG laser treatment with different pulse durations and energy levels. PMMA test specimens were fabricated and each received one of six surface treatments: no treatment (control), and five Er:YAG laser treatments comprising (1) 100 mJ, 1 W, long pulse duration, (2) 200 mJ, 2 W, long pulse duration, (3) 200 mJ, 2 W, very short pulse duration, (4) 300 mJ, 3 W, long pulse duration, and (5) 400 mJ, 4 W, long pulse duration. The resilient liner specimens (n = 15) were processed between two PMMA blocks. The tensile strengths of the bonds between the liners and PMMA were determined using a universal testing machine at a crosshead speed of 5 mm/min. The mode of failure was characterized as cohesive, adhesive, or mixed modes. One-way ANOVA and the post hoc Tukey-Kramer multiple comparisons test were used to analyze the data (α = 0.05). There was a statistically significantly difference in tensile bond strength between laser-treated and untreated specimens (P < 0.05). The 300-mJ, 3 W, long pulse duration laser treatment produced the highest mean tensile bond strength. In addition, the long pulse duration treatments resulted in greater bond strength than very short pulse duration treatment (P < 0.05). Laser irradiation produced significant surface texture changes of the denture base material and improved the adhesion between denture base and soft lining material. In addition, different pulse durations and energy levels were found to effectively increase the strength of the bond.
Failure of the bond between the acrylic resin and resilient liner material is commonly encountered in clinical practice. The purpose of this study was to investigate the effect of different surface treatments (sandblasting, Er:YAG, Nd:YAG, and KTP lasers) on tensile bond strength of silicone-based soft denture liner. Polymethyl methacrylate test specimens were fabricated and each received one of eight surface treatments: untreated (control), sandblasted, Er:YAG laser irradiated, sandblasted + Er:YAG laser irradiated, Nd:YAG laser irradiated, sandblasted + Nd:YAG laser irradiated, KTP laser irradiated, and sandblasted + KTP laser irradiated. The resilient liner specimens (n = 15) were processed between two polymethyl methacrylate (PMMA) blocks. Bonding strength of the liners to PMMA were compared by tensile test with the use of a universal testing machine at a crosshead speed of 5 mm/min. Kruskal-Wallis and Wilcoxon tests were used to analyze the data (α = 0.05). Altering the polymethyl methacrylate surface by Er:YAG laser significantly increased the bond strengths in polymethyl methacrylate/silicone specimens, however, sandblasting before applying a lining material had a weakening effect on the bond. In addition, Nd:YAG and KTP lasers were found to be ineffective for increasing the strength of the bond.
Objective: It was the aim of this study to compare the efficacy of ozone therapy and drug treatment in patients with painful temporomandibular joint (TMJ) disorder (TMD). Subjects and Methods: A total of 63 patients with TMD were enrolled; 33 were treated with bio-oxidative therapy and 30 with a ketoprofen tablet thiocolchicoside capsule 2 × 1 for 7 days. Maximum voluntary interincisal mouth opening (MMO) was measured in millimeters using a scale and recorded during the pre- and posttreatment periods. The patients evaluated their subjective pain using a visual analogue scale (VAS). Data were analyzed using the Mann-Whitney U test, the Kolmogorov-Smirnov test, and the independent t test. Results: The mean MMO of the group that received ozone therapy during the pretreatment period was 46.51 ± 8.2 mm, and it immediately increased to 48.78 ± 7.5 mm after 1 week of ozone therapy, which was statistically significant (p = 0.04). For those who received medication, the mean MMO during the pretreatment period was 46.30 mm, and at the end of 1 week it was 46.9 mm. In the ozone group, 29% of patients showed a gradual decrease in their VAS pain scores compared to pretreatment values (6.3 ± 2.1 to 3.0 ± 2.2). In the medication group, 24% of patients showed a significant decrease in VAS pain scores during the follow-up period (6.9 ± 1.4 to 5.0 ± 1.5). Conclusion: This study showed that bio-oxidative therapy was a more effective treatment than medication therapy for relieving TMJ pain.
There was no accordance between the F-initial and F-max values of the LD, RNC, and FEL after chewing simulation with thermocycling resembling 5 years of clinical functional use. LD had the highest fracture resistance during the fracture test. RNC had low fracture resistance; however, it had considerably high fracture resistance during the fracture test. FEL had considerably low fracture resistance values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.