The glomerular microvasculature is particularly susceptible to injury in thrombotic microangiopathy, but the mechanisms by which this occurs are unclear. We report the cases of six patients who were treated with bevacizumab, a humanized monoclonal antibody against vascular endothelial growth factor (VEGF), in whom glomerular disease characteristic of thrombotic microangiopathy developed. To show that local reduction of VEGF within the kidney is sufficient to trigger the pathogenesis of thrombotic microangiopathy, we used conditional gene targeting to delete VEGF from renal podocytes in adult mice; this resulted in a profound thrombotic glomerular injury. These observations provide evidence that glomerular injury in patients who are treated with bevacizumab is probably due to direct targeting of VEGF by antiangiogenic therapy.
Objective To determine the clinical effectiveness of wound edge protection devices in reducing surgical site infection after abdominal surgery.Design Multicentre observer blinded randomised controlled trial.Participants Patients undergoing laparotomy at 21 UK hospitals.Interventions Standard care or the use of a wound edge protection device during surgery.Main outcome measures Surgical site infection within 30 days of surgery, assessed by blinded clinicians at seven and 30 days and by patient’s self report for the intervening period. Secondary outcomes included quality of life, duration of stay in hospital, and the effect of characteristics of the patient and operation on the efficacy of the device.Results 760 patients were enrolled with 382 patients assigned to the device group and 378 to the control group. Six patients in the device group and five in the control group did not undergo laparotomy. Fourteen patients, seven in each group, were lost to follow-up. A total of 184 patients experienced surgical site infection within 30 days of surgery, 91/369 (24.7%) in the device group and 93/366 (25.4%) in the control group (odds ratio 0.97, 95% confidence interval 0.69 to 1.36; P=0.85). This lack of benefit was consistent across wound assessments performed by clinicians and those reported by patients and across all secondary outcomes. In the secondary analyses no subgroup could be identified in which there was evidence of clinical benefit associated with use of the device.Conclusions Wound edge protection devices do not reduce the rate of surgical site infection in patients undergoing laparotomy, and therefore their routine use for this role cannot be recommended.Trial registration Current Controlled Trials ISRCTN 40402832
Dexmedetomidine markedly increased the range of temperatures not triggering thermoregulatory defenses. The drug is thus likely to promote hypothermia in a typical hospital environment; it is also likely to prove an effective treatment for shivering.
We studied the pharmacokinetic and sympatholytic effects of dexmedetomidine during the immediate postoperative period and found that during this period, the published pharmacokinetic data slightly overshoot target plasma dexmedetomidine concentrations. We also found that heart rate, blood pressure, and plasma catecholamine concentrations decrease during dexmedetomidine infusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.