Using an airway management training model, we have assessed anaesthesia personnel in their use of correct cricoid force and ability to retain this skill after a short training programme. A perspex device, working on a hydraulic principle, was used to measure cricoid pressure when applied to the model. After initial assessment at two levels of cricoid force (20 and 40 N), participants undertook additional training on 3 consecutive days. Thereafter, available participants underwent reassessment at 14-21 days. Forty-nine anaesthetic assistants and anaesthetists underwent initial assessment and 18 completed the full training and reassessment. Untrained, the majority (63%) of participants applied inadequate cricoid force with a wide variation (mean 16.8 (SD 9.3) (range 4.5-43.0) at 20 N and 32.9 (13.3) (14.9-74) at 40 N). After a single training session there was a marked improvement in application of cricoid force. Two additional training sessions did not provide further improvement. After 14-21 days the ability of participants to apply correct cricoid force was retained by 72% of subjects. Those who applied inadequate cricoid force initially were more likely to do so even after training. Most subjects applied too great a cricoid force in the first 5 s of application followed by a progressive loss of force during the next 20 s. This trend improved after training. We conclude that the majority of untrained personnel apply inadequate cricoid force, placing patients at risk of aspiration of gastric contents. While a simple training programme improved application of cricoid force, retained for up to 3 weeks, there was often a substantial decrease in the force applied to the cricoid during a single application, even after training.
Twenty parturients undergoing elective Caesarean section were allocated randomly to receive crystalloid preload 20 ml kg-1 over either 20 min or 10 min before spinal anaesthesia. Significant hypotension (systolic arterial pressure less than 100 mm Hg and less than 80% of baseline value) occurred in six of the 10 patients in the 20-min preload group and seven of 10 patients in the 10-min preload group (ns). Both groups had a significant (P less than 0.05) increase in central venous pressure during the preload period. The mean central venous pressure in the 10-min group was 11.9 mm Hg (range 6-19 mm Hg), which was significantly greater (P less than 0.05) than that in the 20-min group (mean 7.3 mm Hg, range 2-13 mm Hg). Three patients in the 10-min group had clinically unacceptable increases in central venous pressure. This study has demonstrated that rapid administration of crystalloid preload before spinal anaesthesia did not decrease the incidence or severity of hypotension, and questions the role of crystalloid preload.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.