The negative-ion based neutral beam injector for heating and current drive of the ITER plasma (ITER HNB) is under development, at present focusing on the optimization of the full-scale plasma source in the SPIDER test stand. The production of H- or D- ions in the ion source is based on the low work function surfaces obtained by caesium evaporation. This paper describes the caesium conditioning procedure and the corresponding beam performances during the first operation of SPIDER with caesium. Technical solutions to overcome present limitations of the test stand are described. The influence of source parameters on the caesium effectiveness was investigated in short beam pulse operation; with total RF power of 400 kW and filling pressure below 0.4 Pa, and a limited number of extraction apertures, a negative ion current density of about 200 A/m2 was extracted in hydrogen, with beam energy lower than 60 keV. Beam optics and beam uniformity were assessed thanks to the acceleration of isolated ion beamlets. A possible procedure to accelerate a uniform beam was demonstrated at low RF power. The results obtained in this first investigation provided key indications on the operation of one of the largest existing sources of accelerated negative hydrogen-like ions.
SPIDER is the 100 keV full-size Negative Ion Source prototype of the ITER Neutral Beam Injector, operating at Consorzio RFX in Padova, Italy. The largest Negative Ion Source in the world, SPIDER generates an RF driven plasma from which Deuterium or Hydrogen negative ions are produced and extracted. At the end of 2021, a scheduled long-term shutdown started to introduce major modifications and improvements aiming to solve issues and drawbacks identified during the first three years of SPIDER operations. The first action of the shutdown period was the disassembly and characterization of the SPIDER beam source after removal from the vacuum vessel and its placement inside the clean room. Each component was carefully assessed and catalogued, following a documented procedure. Some source components, i.e., the Plasma Grid, Extraction Grid and Bias Plate, revealed the presence of different and non-uniform red, white and green coatings that might be correlated to back-streaming positive ions impinging on grid surfaces, electrical discharges and caesium evaporation. Thus, several analyses have been carried out to understand the nature of such coatings, with the study still ongoing. The evidence of caesium evaporation and deposition on molybdenum-coated SPIDER components, such as the formation of oxides and hydroxides, is demonstrated through surface characterization analyses with the use of the Scanning Electron Microscope (SEM), X-ray Diffraction (XRD) and X-ray Photoelectron Spectroscopy (XPS).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.