Epi-LASIK resulted in a significant change in CH and CRF postoperatively. Although some recovery occurred over time, CH, CRF, and IOP did not revert to preoperative levels.
When added to a standardized postoperative pain regimen, gabapentin use led to no additional improvement in PRK pain control compared with a placebo at the dose and the time intervals tested.
Epi-LASIK showed superior refractive efficacy and stability but required more time for wound healing, resulting in inferior early visual outcomes and a tendency to overcorrect higher refractive errors compared to PRK. Both treatments were safe and comparable in terms of pain and haze formation.
Subjective refractive error for white light can be accurately and precisely predicted objectively from monochromatic wavefront aberrations obtained for near-infrared light, but intersubject variability limits accuracy for individual subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.