International audienceParis conurbation is a heavily urbanized but weakly industrialized catchment. Recently, it has been shown at the scale of Paris that alkylphenols (AP) and phthalates (PAE) are not rejected by the industry, but they originate from domestic wastewater at more than 95 %. However, the contribution of the different types of greywater to the pollution by alkylphenols and phthalates was not addressed. This work aims at providing new insights on this particular point. Hence, the concentration of four phthalates (diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), benzyl butyl phthalate (BBP), and di(2-ethylhexyl)phthalate (DEHP)) and two alkylphenols (octylphenols (OP) and isomers of nonylphenol (NP)) were followed in greywater. For each sample, analyses were carried out on both the dissolved and particulate phases. Moreover, water quality parameters were also monitored, in order to find out whether or not any correlation exists between the concentration of the investigated contaminants and the quality of water. Water quality parameters studied are pH, total suspended solids (TSS), dissolved and particular organic carbon (DOC and POC), chemical and biochemical oxygen demands (COD and BOD5), total Kjeldahl nitrogen (TKN), and anionic detergents (methylene blue active substance or MBAS). This paper presents the methodology used to monitor two greywater with the most important volumes: showers and washing machines. These greywater showed high variability with regard to water quality parameters. Moreover, AP and PAE concentrations are given for the first time for these two types of greywater. All compounds except OP were observed in almost all samples in at least one of the two monitored phases. The concentrations varied between limit of quantification for OP and 102 μg/l for DEHP. The levels measured in washing machines were higher than those for showers for all compounds. For instance, median NP concentration in washing machines was 3.59 μg/l against 1.09 μg/l in showers, DEHP was observed at 102 μg/l in washing machines against 16.6 μg/l in showers. Variability of the results was explained by habits of individuals (shower time, number of products used…) but also by differences in product composition. However, each type of water exhibited the same distribution. NP was the most abundant AP (about 85 % of the total amount) while DEHP represented the two thirds of the PAE compounds. The partition coefficients (Kd in l/kg) were evaluated. The results showed that log Kd ranged between 2.1 (DEP) and 4.8 (DEHP). Log Koc presented similar trends lying in the 2.4 (DEP)-5.0 (DEHP) range. Finally, with regard to greywater quality, the application for greywater reuse is discussed
To promote breast feeding and breast pumping is essential for the most vulnerable infants even if the current coronavirus disease 2019 (COVID-19) pandemic sanitary crisis imposes more stringent hygienic measures. As recommended by the Centers for Disease Control and Prevention, World Health Organization, and Milk Bank Association, “after each pumping session, all pump part that come into contact with breast milk should be appropriately disinfected.” The present study proposed different methods than can be used and focus on the safety analysis of chlorine solution (CS) in terms of residual hypochlorous acid (HCA) and total trihalomethanes (THM). We also performed an efficacy testing of the CS approach to decontaminate the devices used to collect the milk (breast pumps and bottles). The bacteriologic results of 1,982 breast pump milk samples collected in three different settings showed a major decrease of the microbial contamination using either sterile device or decontamination with CS compared to a simple soap washing. The main messages from our study are to propose a guideline for the safe use of CS and to define situations when breast pump decontamination might be necessary: vulnerable babies for which sterile device is recommended; special circumstances, for example the current COVID-19 pandemic; special situations, for example women living in precarious conditions; or women pumping their milk at work but that would have low or no access to boiled water. Overall, cold decontamination reduced losses of milk for bacteriological reasons in human milk banks and may also be interesting to prevent horizontal contamination by virus like COVID-19.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.