This project involves the development of a prototype electrical generator for delivering and storing small amounts of electricity. Power is generated using the thermoelectric effect. A single thermoelectric generator (TEG) is utilised to convert a small portion of the heat flowing through it to electricity. The electricity produced is used to charge a single rechargeable 3.3 Volt lithium-iron phosphate battery. This study investigates methods of delivering maximum power to the battery for a range of temperature gradients across the thermoelectric module. The paper explores load matching and maximum power point tracking techniques. It was found that, for the TEG tested, a SEPIC DC-DC converter was only beneficial for temperature gradients less than 100 ⁰C across the TEG. At a temperature gradient of 150 ⁰C, the effective resistance of the battery was close to the internal resistance of the TEG. For temperature gradients in excess of 100°C a DC-DC converter is not suggested and a simple charge protection circuit is sufficient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.