Current methods for measuring cerebral blood volume (CBV) in newborn infants are unsatisfactory. A new method is described in which the effect of a small change (5-10%) in arterial oxygen saturation (SaO2) on cerebral oxyhemoglobin [HbO2] and deoxyhemoglobin [Hb] concentration is observed by near-infrared (NIR) spectroscopy. Previous experiments in which the NIR absorption characteristics of HbO2 and Hb and the pathlength of NIR light through the brain were defined allowed changes in [HbO2] and [Hb] to be quantified from the Beer-Lambert law. It is shown here that CBV can then be derived from the expression CBV = (delta[HbO2] - delta[Hb])/(2. delta SaO2.H.R.), where H is the large vessel total hemoglobin concentration and R to the cerebral-to-large vessel hematocrit ratio. Observations on 12 newborn infants with normal brains, born at 25-40 wk of gestation and aged 10-240 h, gave a mean value for CBV of 2.22 +/- 0.40 (SD) ml/100 g, whereas mean CBV was significantly higher 3.00 +/- 1.04 ml/100 g in 10 infants with brain injury born at 24 to 42 wk of gestation and aged 4-168 h (P less than 0.05).
A noninvasive method of measuring hemoglobin flow through an organ by near-infrared spectroscopy (NIRS) is described that allows blood flow to be calculated. The method is derived from the Fick principle and uses a small change in arterial oxyhemoglobin concentration (brought about by a change in the fractional inspired O2 concentration) as an intravascular tracer. Changes in deoxyhemoglobin and oxyhemoglobin concentrations are quantified by monitoring variations in the absorption of near-infrared light in the organ, thus providing a measure of tracer accumulation. The tracer input function is calculated from the change in arterial O2 saturation, measured by pulse oximetry. The method was used to determine hemoglobin flow in the forearms of six healthy young adults on 10 occasions. Forearm hemoglobin flow ranged from 22.5 to 82.6 mumol.l-1.min-1. Calculated forearm blood flow ranged from 1.01 to 4.01 ml.100 g-1.min-1. For comparison, forearm blood flow was measured by venous occlusion plethysmography, and the relation between flow calculated by NIRS (y) and plethysmography (x) was y = 0.93x + 0.30 (r2 = 0.95). The mean difference between the methods was 0.14 ml.100 g-1.min-1. The technique may be widely applicable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.