Elevated MMP-9 concentration is associated with carotid plaque instability and the presence of macrophages, factors that indicate increased risk for a neurological event. Determination of this gelatinase may enable identification of high-risk subgroups of patients with carotid artery stenosis.
Background and Purpose Inflammatory biomarkers predict incident and recurrent cardiac events, but their relationship to stroke prognosis is uncertain. We hypothesized that high-sensitivity C-reactive protein (hsCRP) predicts recurrent ischemic stroke after recent lacunar stroke. Methods Levels of Inflammatory Markers in the Treatment of Stroke (LIMITS) was an international, multicenter, prospective ancillary biomarker study nested within Secondary Prevention of Small Subcortical Strokes (SPS3), a Phase III trial in patients with recent lacunar stroke. Patients were assigned in factorial design to aspirin versus aspirin plus clopidogrel, and higher versus lower blood pressure targets. Patients had blood samples collected at enrollment, and hsCRP measured using nephelometry at a central laboratory. Cox proportional hazards models were used to calculate hazard ratios and 95% confidence intervals (HR, 95%CI) for recurrence risks before and after adjusting for demographics, comorbidities, and statin use. Results Among 1244 lacunar stroke patients (mean 63.3 ± 10.8 years), median hsCRP was 2.16 mg/L. There were 83 recurrent ischemic strokes (including 45 lacunes), and 115 major vascular events (stroke, myocardial infarction, vascular death). Compared with the bottom quartile, those in the top quartile (hsCRP >4.86 mg/L) were at increased risk of recurrent ischemic stroke (unadjusted HR 2.54, 95%CI 1.30–4.96), even after adjusting for demographics and risk factors (adjusted HR 2.32, 95%CI 1.15–4.68). HsCRP predicted increased risk of major vascular events (top quartile adjusted HR 2.04, 95%CI 1.14–3.67). There was no interaction with randomized antiplatelet treatment. Conclusions Among recent lacunar stroke patients, hsCRP levels predict risk of recurrent strokes and other vascular events. HsCRP did not predict response to dual antiplatelets.
Increased hs-CRP levels may be related to the presence of macrophages and T lymphocytes in plaque, which is associated with the phenomena of instability that can lead to development of an ischemic event. Thus determination of circulating hs-CRP levels may be a useful additional marker of risk in patients with high-grade carotid stenosis.
Background and aim: biliary self-expanding metal stents (SEMS) have the advantage of being inserted undeployed with very small sizes and provide, when fully opened, large diameters for biliary drainage. However, their use in benign conditions has been very limited, mainly because of difficulty in their extraction. We present our initial experience with a fully covered SEMS (Wallflex) for the management of benign problems of the bile duct. Patients and methods: in a prospective study, stents of 8 mm in diameter and 4, 6 or 8 cm long were inserted by means of ERCP. These SEMS were chosen when according to medical judgement it was thought that diameters greater than 10 French (3.3 mm) were needed for proper biliary drainage. Stents were extracted also endoscopically, several months later when deemed clinically appropriate. Results: twenty biliary SEMS were inserted. Reasons for insertion were: large intrahepatic biliary fistula after hydatid cyst surgery (1), perforation of the papillary area following endoscopic sphincterotomy (2), coaxial insertion to achieve patency in obstructed uncovered stents inserted in benign conditions (3), benign strictures (7), multiple and large common bile duct stones that could not be extracted because of tapering and stricturing of the distal common bile duct (7). In all cases, successful biliary drainage was achieved and there were no complications from insertion. Stents were easily extracted after a mean time of 132 days (36-270) in place. Complete resolution of biliary problems was obtained in 14 patients (70%). Conclusions: in our initial experience, the fully covered Wallflex biliary stent was removed without any complication after being in place in the common bile duct for a mean time of over four months. Therefore, it could be used in the management of benign biliary conditions.
Background and aim: endoscopic retrograde cholangiopancreatography (ERCP) with biliary sphincterotomy (BS) is the usual method for extracting common bile duct stones. However, following BS and by means of extraction balloons and Dormia baskets a complete bile duct clearance cannot be achieved in all cases. We present a study on the impact that hydrostatic balloon dilation of a previous BS (BSD) may have in the extraction rate of choledocholithiasis. Patients and methods: a prospective study which included 91 consecutive patients diagnosed with choledocholithiasis who underwent ERCP. For stone removal, extraction balloons and Dormia baskets were used, and when necessary BSD was employed. Results: complete bile duct clearance was achieved in 86/91 (94.5%) patients. BSD was used in 30 (33%) cases. In these cases, extraction was complete in 29/30 (97%); 23 (76%) patients in the BSD group had anatomic difficulties or bleeding disorders. The most frequently used hydrostatic balloon diameter was 15 mm (60%). There were 7 (7.6%) complications: two self-limited hemorrhage episodes in the BSD group and one episode of cholangitis, one of pancreatitis, and three of bleeding in the group in which BSD was not used. Conclusions: BSD is a very valuable tool for extracting common bile duct stones. In our experience, there has been an increase in the extraction rate from 73% (Rev Esp Enferm Dig 2002; 94: 340-50) to 94.5% (p = 0.0001, OR 0.1, CI 0.05-0.45), with no increase in complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.