This study was designed to: (1) determine plasma midazolam concentrations producing adequate sedation in ICU patients; (2) establish an intravenous regimen to provide continuous sedation and rapid recovery after discontinuation of infusion. Initially, 13 ICU patients were given midazolam as a bolus injection, 0.20 mg.kg-1 over 30 s in order to define the midazolam plasma concentration corresponding to an adequate level of sedation. The optimal level was reached in a mean time of 61 +/- 26 min and the mean corresponding midazolam plasma concentration was 163 +/- 62 ng.ml-1. Estimations of the main pharmacokinetic parameters (elimination half life: 230 +/- 102 min, total body clearance: 520 +/- 283 ml.min-1, total volume of distribution: 2.23 +/- 1.15 l.kg-1) showed no marked differences with normal patients. From those variables, an infusion regimen (loading dose and maintenance rate) to provide long term (24 to 80 h) sedation was derived in 9 patients. The mean loading dose was 0.33 +/- 0.18 mg.kg-1 over 30 min and the mean continuous infusion dose was 0.06 +/- 0.02 mg.kg-1.h-1. The mean midazolam plasma concentration during infusion was 215 +/- 61 ng.ml-1, and the mean midazolam plasma concentration at the end of infusion was 199 +/- 93 ng.ml-1. The level of sedation was considered as optimal in most patients throughout the study. After discontinuation of infusion, the mean time for normalization of the mental state was 97 min.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations鈥揷itations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.